background image

126

40mm

Bushing

电工套管

    注意:供水管中心尺寸要求如上图。

供水管应凸出墙面

22-32mm

,否则将影响止水阀安装

及调节。

电工套管与墙面齐平,否则也将影响止水阀安装及调
节。

供水管内径不得小于

10MM,

否则将会影响冲洗效果。

        NOTE:

Roughing-in dimension requirements for 

supply tubing as shown.

Supply tubing is 22-32mm out of the wall. Otherwise. 
stop valve can not be installed and adjuested properly.

Bushing flush with the wall, Otherwise, stop valve can 
not be installed and adjusted properly too.

Inner diameter of supply tubing is no less than 10mm, 
otherwise the flushing will be affected.

1/2”N.P.S INLET

FOR STOP VALVE

止水阀连接

362mm

146±20mm

20mm

152mm

2”N.P.S TAP

内螺纹

OUTLET DETAILS

出水口详细图

2”N.P.S TAP

内螺纹

OUTLET DETAILS

出水口详细图

1/2”N.P.S INLET

FOR STOP VALVE

止水阀连接

152mm

1

2mm

20mm

Bushing

电工套管

610mm+10

0 mm

2”N.P.S TAP

内螺纹

533mm

603mm

76mm

*610mm

838mm

464mm

305mm

1029mm

To Floor

到地面

Fig.#2

2

22-32mm

70mm

610mm+10

0 mm

533mm

2”N.P.S TAP

内螺纹

603mm

76mm

*610mm

838mm

464mm

305mm

1029mm

To Floor

到地面

Fig.#1

1

* Recommended dimensions for installation only, please

adjust according to actual situation.

*仅为建议安装尺寸,客户可根据实际情况调整。

2

1146969-T01-

K

Summary of Contents for BARDON VITREOUS CHINA TOUCHLESS K-4915T

Page 1: ...eave instructions for the consumer BEFORE YOU BEGIN A HOW TO USE THESE INSTRUCTIONS A B NOTES Observe all local plumbing and building codes Stop Valve has a 1 2 NPT inlet supply connection Fixture dim...

Page 2: ...g is no less than 10mm otherwise the flushing will be affected 1 2 N P S INLET FOR STOP VALVE 362mm 146 20mm 20mm 152mm 2 N P S TAP OUTLET DETAILS 2 N P S TAP OUTLET DETAILS 1 2 N P S INLET FOR STOP V...

Page 3: ...p valve assembly and tighten connection NOTE Stop valve should face left side of tank when tighten Please clean the inside of water supply pipe before connect ing to the product Plug seal ring into in...

Page 4: ...and the pipes into the tank of urinal Adjust the distance of outlet pipe and plastic pipe Then make the outlet pipe aim at the sealing washer and make the valve assy aim at the outlet of stop valve Pl...

Page 5: ...as below CAUTION a Do not connect 220V AC Power supply to DC wiring terminal b Do not damage the covering of AC power unit or remove screws to avoid leakage K 4915T K 4915T W K 4915T Y 3 K 4915T C05...

Page 6: ...of battery box Tighten the screw otherwise the batteries may be affected with damp Notice a Keep the connector away from water b Don t mistake the direction of inlet and outlet c Do not connect the D...

Page 7: ...the hooks facing opposite the direction illustrated Using a 5 8 wrench assemble and tighen nut washer and lock nut on both sides of urinal CAUTION Risk of chipping or breaking urinal Do not overtighen...

Page 8: ...15T C05 Before power on clear the unwantedobjects in front of the sensor window to shortening the sensing distance When the batteries are nearly exhausted the indicator will flush every 2 seconds the...

Page 9: ...sher disinfect or other deodorizing cleaning solvent directly into the sensor c Keep wire away from water d Don t attack the sensor window 1 8 30 30 Approach the supplied special magnetic stick flushi...

Page 10: ...ng Water Volume Deodorization Flushing Starting Pressure Operation Temperature Ambient water temperature of 1 55 One forced flushing will be conducted if the urinal is being used continuously for 2 mi...

Page 11: ...rn off stop valve flush to clean off water supply line 1 2 3 4 1 2 3 4 1 2 3 4 1 10 2 3 4 1 Urinal is designed or use with potable water Avoid water that includes a lot of contaminants or with acid al...

Page 12: ...VICE PARTS PAGE VITREOUS CHINA TOUCHLESS TM URINAL 1066275 SP 1111671 SP 1128222 SP 1128223 SP 1146974 SP 1146975 SP 1066277 SP 1111672 SP 1148065 SP 16306T NA K 4915T K 4915T W K 4915T WC05 K 4915T C...