3. INSTALL BATTERIES

(Only for DC)

B. When installing the power uint on the ceiling,please 
layout bushing according to Fig.#9 and thread wire through 
the bushing.
Fig.#9: Connection sketch while installing power uint on the 
ceiling.

CAUTION: One AC power unit can supply two sensors            
at most.

B. 

将电源盒放在天花板上,如图示安装电工套管,管

内装入电线。

9:

交流电源盒安装在天花板上的连接示意图。

      

警告:一个交流电源盒最多可连接两个感应区。

 

See Fig.#10
Turn on stop valve. Inspect pipes for leakage in not flushing. 
Connect the connector of sensor window with the connector 
of solenoid valve.

Remove the battery box cover and insert alkaline batteries 
into the battery box.Reinstall the cover of the baottery box 
and tighten it with battery box with screws. Connect the 
connector of battery box with the connector of the sensor 
window.

See the section “Replace Batteries”.

       NOTE: Do not lose the screws when removing the 
cover of battery box. Tighten the screw, otherwise the 
batteries may be affected with damp.

Notice:

a. Keep the connector away from water.
b. Don’t mistake the direction of inlet and outlet.
c. Do not connect the DC output of AC power unit to AC

power supply.

d. Do not connect to power supply while installing. Connection

line is not supplied. AC connection wire with insulating
sleeving is recommended. Wire of which the nominal sectionn
area of conductorisnot less than 0.5mm

2

 is also recommend.

DC connection line use wire of which the nominal section area
is not less than 0.3mm

2

. It is cut according to acted installation

requirements (The length of cut wire is recommended less than
10m).

e. The head AC power supply must be protected with

appropriate fuse.

f. Please confirm the AC power supply and water supply should

be shut off before maintaining the products with AC power
related.

   注意

:

a.

不要让电线接插件接触水。

b.

不要将进出水方向弄错。

c.

不可将交流电源盒的直流输出端与交流电连接。

d.

安装时不要向电源盒供电。连接线请用户自备,建

  

议交流电源线采用导体标称截面积

0.5mm

2

的电线,

  

直流连接线采用导体标称截面积

0.3mm

2

的电线,

  

电线长度根据实际安装需要自行裁剪(建议连接线

  

长度小于

10m

)。

e.

交流电的总电源必须有合适的熔断丝加以保护。

f.

维修时必须断开交流电源并关闭水源。

Fig. #10

10

Fig. #9

9

Ceiling

天花板

Bushing

电工套管

AC Power Unit

交流电源盒

6

1146969-T01-

K

Summary of Contents for BARDON VITREOUS CHINA TOUCHLESS K-4915T

Page 1: ...eave instructions for the consumer BEFORE YOU BEGIN A HOW TO USE THESE INSTRUCTIONS A B NOTES Observe all local plumbing and building codes Stop Valve has a 1 2 NPT inlet supply connection Fixture dim...

Page 2: ...g is no less than 10mm otherwise the flushing will be affected 1 2 N P S INLET FOR STOP VALVE 362mm 146 20mm 20mm 152mm 2 N P S TAP OUTLET DETAILS 2 N P S TAP OUTLET DETAILS 1 2 N P S INLET FOR STOP V...

Page 3: ...p valve assembly and tighten connection NOTE Stop valve should face left side of tank when tighten Please clean the inside of water supply pipe before connect ing to the product Plug seal ring into in...

Page 4: ...and the pipes into the tank of urinal Adjust the distance of outlet pipe and plastic pipe Then make the outlet pipe aim at the sealing washer and make the valve assy aim at the outlet of stop valve Pl...

Page 5: ...as below CAUTION a Do not connect 220V AC Power supply to DC wiring terminal b Do not damage the covering of AC power unit or remove screws to avoid leakage K 4915T K 4915T W K 4915T Y 3 K 4915T C05...

Page 6: ...of battery box Tighten the screw otherwise the batteries may be affected with damp Notice a Keep the connector away from water b Don t mistake the direction of inlet and outlet c Do not connect the D...

Page 7: ...the hooks facing opposite the direction illustrated Using a 5 8 wrench assemble and tighen nut washer and lock nut on both sides of urinal CAUTION Risk of chipping or breaking urinal Do not overtighen...

Page 8: ...15T C05 Before power on clear the unwantedobjects in front of the sensor window to shortening the sensing distance When the batteries are nearly exhausted the indicator will flush every 2 seconds the...

Page 9: ...sher disinfect or other deodorizing cleaning solvent directly into the sensor c Keep wire away from water d Don t attack the sensor window 1 8 30 30 Approach the supplied special magnetic stick flushi...

Page 10: ...ng Water Volume Deodorization Flushing Starting Pressure Operation Temperature Ambient water temperature of 1 55 One forced flushing will be conducted if the urinal is being used continuously for 2 mi...

Page 11: ...rn off stop valve flush to clean off water supply line 1 2 3 4 1 2 3 4 1 2 3 4 1 10 2 3 4 1 Urinal is designed or use with potable water Avoid water that includes a lot of contaminants or with acid al...

Page 12: ...VICE PARTS PAGE VITREOUS CHINA TOUCHLESS TM URINAL 1066275 SP 1111671 SP 1128222 SP 1128223 SP 1146974 SP 1146975 SP 1066277 SP 1111672 SP 1148065 SP 16306T NA K 4915T K 4915T W K 4915T WC05 K 4915T C...

Reviews: