如何连接交流电源

HOW TO CONNECT AC 

POWER SUPPLY

1380339-T01-A

7

一个交流电源供一个感应龙头

One AC Power supply one touchless faucet

220V

交流电

Connect AC 220V

 Faucet

感应龙头

开关

Switch

Wire Tube

穿线管

HOW TO CHANGE TO A MIXING 

SENSOR FAUCET

 

(If customerpurchases  tee inlet assy. 

1298745-SP)

1298745-SP

冷热混水龙头水温调节:先关闭热水

角阀,再将冷水角阀旋至冷水最大状

态,再缓慢打开热水阀,以免烫伤。

如冷水水压大,打开全部热水角阀

后,仍无合适水温,请再缓慢减少冷

水出水量,直至水温使用舒适。

Adjust  the  water  temp  for  faucet  with  temperature 
mixture:  turn  off  hot  water  valve  first,  and  then  turn  on 
the water and adjust to full cold, slowly turn on hot water 
valve  to  avoid  scalding.  If  cold  water  pressure  is  high 
and unable to gain proper comfortable water temp even 
hot  water  valve  is  fully  open,  turn  down  cold  water 
capacity slowly until water temp is comfortable for use. 

建议使用科勒推荐的三通进水软管

组件,否则有冷热水互窜的风险。

It is recommended to use Kohler TEE inlet hose assembly, 

otherwise there is a risk of cold and hot water mixing 

problem. 

Summary of Contents for AVID DUO 29936T-CP

Page 1: ...ing window when installing or cleaning the faucet 4 For new installations install the faucet and drain to the lavatory before installing the lavatory BEFORE YOU BEGIN 158 200436 1955 200444 AVID AVID...

Page 2: ...l light up indicating waving hand for soap solution After clean both hands extending hands under the faucet sensing range again The faucet begins to flow The faucet will auto stop water flow within 0...

Page 3: ...in AVID DUO SENSOR FAUCET AC MIXOR AVID DUO SENSOR FAUCET AC COLD Drain 54 41 2 66 5 31 75 226 191 123 151 135 50 5 Finish the wall Switch 100 Recommended Size 200 Recommended Size 500 Recommended Siz...

Page 4: ...17 15 8 18 1 2 Install Control Assy TECHNICAL SPECIFICATION 48 2 2 4 3 37 5 61 16 15 17 18 Mixer 19 Cold 10 11 12 14 13 Insert faucet soap hose 9 wire 8 and inlet hose 7 through gasket 2 then seat ga...

Page 5: ...oap dispenser pump Fig 3 4 How to Install the Drain Unscrew the drain flange 22 from drain assembly Apply plumbers putty around the bottom circle Insert drain body 23 into lavatory from the underside...

Page 6: ...d ensure proper wiring and connection Close control box cover and turn on AC power supply to activate faucet working status 6 Replenish soap solution 1 Press soap dispenser dismantle button and pull s...

Page 7: ...ith temperature mixture turn off hot water valve first and then turn on the water and adjust to full cold slowly turn on hot water valve to avoid scalding If cold water pressure is high and unable to...

Page 8: ...ersely affect the surface and it is not recommended for cleaning Do not use abrasive cleaners or solvents on Kohler faucets and fittings HOW TO CHANGE TO A THERMOSTATIC SENSOR FAUCET If users purchase...

Page 9: ...ntrol assembly water inlet 3 24 JMP1 1 2 24 JMP2 1 2 3 Self Cleaning the stagnant water When the faucet is no used for a long period of time it will automatically flush to discharge the stagnant water...

Page 10: ...is closed Filter device is blocked Clogged foam soap cartridge Remove objects Clean window Inspect terminal Open valve Clean filter Clean foam cartridge The stop valve is not open completely The Aera...