background image

INSTALLATION

How to Install the Faucet

(11)

螺钉

(12)

(10)

(13)
(14)

注意

Secure faucet on lavatory

Unscrew  valve  cover  screw  (11)  with a 

screwdriver and open valve cover (10).  

Determine  proper  mounting  location per 

rough  –in  (Fig  1),  then  punch expansion 

tube (13) in. Place valve box against the 

wall and then secure control valve 

assembly on the wall by bolts (14).  

Note:  Place  the  long  end  of  control  box 

upright,  water  outlet  position  shall  be 

adjusted left/right based on requirements.

For mixture faucet, connect hose (16) one 

end to Tee inlet hose assembly (17), and 

then another end to control assembly (15) 

water  inlet;  connect  water  outlet  marked 

with “water outlet hose” faucet outlet hose 

(8),  Tee  inlet  hose  assembly  connect  to 

another two ends with angle valve (18). 

For  cold  water  faucet,  connect  hose  (16) 

one  end  to  control  assembly  (15)  filter 

(19), another end connect to angle valve, 

then  connect  control  assembly  outlet 

marked  with  “water  outlet  hose”  to  faucet 

outlet hose (8). 

1380339-T01-A

4

对于单冷龙头,将软管

(16)

一端与控制

组件

(15)

的滤网

(19)

相连,另一端与角

阀连接,再将控制组件出水口与标有

 

“出水管”的龙头

出水

软管

(8)

连接。

对于冷热混水龙头,将软管

(16)

一端与

三通进水软管组件

(17)

连接,另一端与

控制组件

(15)

进水口连接,再将出水口

与标有“出水管”的龙头

出水

软管

(8)

连接,三通进水软管组件另外两端与角

(18)

连接。

1.

2.

Install Control Assy

  TECHNICAL SPECIFICATION

48

22--   4.3

37.5

61

16

15

17

18

混水

(Mixer)

19

单冷

(Cold)

10

11

12

14

13

Insert faucet soap hose (9)/wire (8) and 

inlet hose (7) through gasket (2), then seat 

gasket (2) in the groove on the underside of 

the faucet. Insert faucet soap hose (9)/wire 

(8) and inlet hose (7) through lavatory 

mounting hole, then insert gasket (3), tab 

(4) retainer (5) through soap hose (9)/wire 

(8), fasten retainer on stud as shown in the 

directions, Last, fasten two screws (6) on 

retainer, press tab (4) from the top of 

screws to secure the faucet.

2

1

4

3

5

8

6

9

7

将龙头给皂软管

(9)

及线

(8)

和进水软管

(7)

穿过橡胶垫片

(2)

,并将橡胶垫片

(2)

嵌入龙头

(1)

底部的盘槽中,再将给皂

软管

(9)

及线

(8)

和进水软管

(7)

从面盆安

装孔穿过,从台盆下方依次将垫片

(3)

压片

(4)

固定环

(5)

穿过给皂软管

(9)

及线

(8)

和进水软管

(7)

,将固定环按照图示

方向拧在牙管上,用十字螺丝刀将两个
螺钉

(6)

紧固在固定环上,由螺钉端部

压紧压片

(4)

固定水龙头。

220V

50/60Hz

0.5GPM

1.9L/min

1

4000MPa·s

Power: AC 220V, 50/60Hz
Senser Duration: Less than 0.5s
Shut-off Delay: 0.5~1s
Sensing Distance: Automatic adjustment
Flow Rate: 

0.5GPM (About 1.9L/min )     

 

Overtime Flowing Control: Automatically stop flushing 
when the faucet senses an object for more than 1 minute 
continuously
Ambient Temperature: 1~40
Supply Water Temperature: 0.5~71

Supply Water Pressure: 0.05~0.86MPa
Liquid soap volume: about 1.0mL

0.5

0.5

1

适用皂液粘度:
皂液瓶容量:约

1500mL

 1

40

0.5

 71

0.05

0.86MPa

出皂液量:约

1.0mL

4000MPa  s

·

Applicable liquid soap viscosity: 1
Soap solution bottle capacity: about 1500m

L

Summary of Contents for AVID DUO 29936T-CP

Page 1: ...ing window when installing or cleaning the faucet 4 For new installations install the faucet and drain to the lavatory before installing the lavatory BEFORE YOU BEGIN 158 200436 1955 200444 AVID AVID...

Page 2: ...l light up indicating waving hand for soap solution After clean both hands extending hands under the faucet sensing range again The faucet begins to flow The faucet will auto stop water flow within 0...

Page 3: ...in AVID DUO SENSOR FAUCET AC MIXOR AVID DUO SENSOR FAUCET AC COLD Drain 54 41 2 66 5 31 75 226 191 123 151 135 50 5 Finish the wall Switch 100 Recommended Size 200 Recommended Size 500 Recommended Siz...

Page 4: ...17 15 8 18 1 2 Install Control Assy TECHNICAL SPECIFICATION 48 2 2 4 3 37 5 61 16 15 17 18 Mixer 19 Cold 10 11 12 14 13 Insert faucet soap hose 9 wire 8 and inlet hose 7 through gasket 2 then seat ga...

Page 5: ...oap dispenser pump Fig 3 4 How to Install the Drain Unscrew the drain flange 22 from drain assembly Apply plumbers putty around the bottom circle Insert drain body 23 into lavatory from the underside...

Page 6: ...d ensure proper wiring and connection Close control box cover and turn on AC power supply to activate faucet working status 6 Replenish soap solution 1 Press soap dispenser dismantle button and pull s...

Page 7: ...ith temperature mixture turn off hot water valve first and then turn on the water and adjust to full cold slowly turn on hot water valve to avoid scalding If cold water pressure is high and unable to...

Page 8: ...ersely affect the surface and it is not recommended for cleaning Do not use abrasive cleaners or solvents on Kohler faucets and fittings HOW TO CHANGE TO A THERMOSTATIC SENSOR FAUCET If users purchase...

Page 9: ...ntrol assembly water inlet 3 24 JMP1 1 2 24 JMP2 1 2 3 Self Cleaning the stagnant water When the faucet is no used for a long period of time it will automatically flush to discharge the stagnant water...

Page 10: ...is closed Filter device is blocked Clogged foam soap cartridge Remove objects Clean window Inspect terminal Open valve Clean filter Clean foam cartridge The stop valve is not open completely The Aera...

Page 11: ...10 Pb Hg PBB PBDE Cd Cr VI GB T 26572 GB T 26572 10 1380339 T01 A 11...

Page 12: ...f these hazardous materials used in this product The product service life for environment protection is 10 years Kohler Company will specify product service life based on product characteristics The p...

Reviews: