7. Protective Flushing
When the toilet has not been used for a long time, the sensor
will drive the solenoid valve to flush every 24 hours to avoid
the deodorizer and the sewer pipe from drying up.
7.
24
-16-
Toilet & Squat Repair
When repairing, you don t have to dismount the sensor.
Cover the sensing window with tape and work with ease.
:
use very adhesive tape in case the scar
will be hard to remove and result in false
operations of the sensor.
Notice
Don't
/
Clean the Filter Screen
If the flushing volume reclines sharply after installation or
used for a long time with no cause from water pressure, the
filter may need a wash. Turn off the fixed cap with filter-key,
take out the filter, clean with a brush and reinstall it.
a. Turn off the water supply or tighten the
adjusting bolt before cleaning.
b. Carefully take out the filter when cleaning to
avoid foreign materials entering the inside
of the valve body.
Notice:
MAINTENANCE
Care & Clean
Keep the sensing window clean. Wipe with soft cloth and mild
cleaner.
a. Do not use dust-removing powder, abrasive
powder or cleaner containing oil, acid or
alkaline ingredient.
b. Do not spray air-refresher, disinfector, or
other deodorizing, cleaning solvent directly
into the sensing window.
c. Keep wire away from water.
d. Don t attack the sensor window.