TP-6071 3/00
12
Section 4 Fuel System
6. Toggle the start/stop switch until fuel, free of air
bubbles, flows from vent screw C. Tighten the vent
screw.
1
2
3
4
5
1. Vent screw B
2. Vent screw A
3. Fuel filter
4. Vent screw C
5. Fuel injection pump
607142
Figure 4-2
Bleeding the Fuel System
4.4 Fuel Pump
The fuel pump transfers fuel from a source to the
injection pump.
Fuel Pump Test Procedure:
1. Remove the two leads at the bottom of the fuel
pump. The pump terminals are labeled (--) and (+).
See Figure 4-3.
2. Connect the inlet side of the pump to a fuel source.
Disconnect the outlet hose from the fuel filter and
place the hose end in a container to catch the fuel.
3. Connect the positive (+) terminal of a 12-volt
battery to the positive terminal of the fuel pump.
Connect the negative terminal of the fuel pump to
the negative (--) terminal of the battery. You should
hear the pump operate and see fuel discharge from
the pump outlet. Replace the pump if it does not
operate.
4. Connect a pressure gauge to the outlet side of the
fuel pump. Repeat step 3
.
See Section 1.3 for the
specified fuel pump pressure ratings.
I-940
1
2
3
4
1. Fuel inlet
2. Negative (--) terminal
3. Positive (+) terminal
4. Fuel outlet
Figure 4-3
Fuel Pump
Summary of Contents for 11.5EFOZ
Page 2: ......
Page 4: ...TP 6071 3 00 Table of Contents...
Page 10: ...TP 6071 3 00 VI Safety Precautions and Instructions Notes...
Page 18: ...TP 6071 3 00 6 Section 1 Specifications Notes...
Page 26: ...TP 6071 3 00 14 Section 4 Fuel System Notes...
Page 50: ...TP 6071 3 00 38 Section 7 Generator Troubleshooting Notes...
Page 60: ...TP 6071 3 00 48 Section 9 Generator Disassembly Reassembly Notes...
Page 66: ...TP 6071 3 00 54 Section 10 Wiring Diagrams Notes...
Page 67: ...TP 6071 3 00 55 Section 10 Wiring Diagrams 10 6 Wiring Diagram 4 Lead 229937 C...
Page 68: ...TP 6071 3 00 Section 10 Wiring Diagrams 56 10 7 Wiring Diagram 12 Lead 229938 A...