TP-6053 7/04
15
Section 4 Fuel System
6
5
4
TP-5586-3
9/10EOZ and 8/9EFOZ Models
5/8EOZ and 4/6.5EFOZ Models
1
2
1
2
4
5
6
3
1. Vent screw, position 1
2. Vent screw, position 2
3. Fuel return
4. Fuel filter
5. Fuel injection pump
6. Vent screw, position 5
Figure 4-4
Fuel System Bleed Points, Typical
4.5 Fuel Solenoid
The fuel solenoid serves to pull the injector pump lever
to the fuel-on position when energized.
The fuel
solenoid is spring loaded to return the injector-pump
lever to the fuel-off position when deenergized.
The generators in this manual use a 3-lead fuel
solenoid.
This solenoid has a white lead (P) which
energizes the pull-in coil only during cranking. During
operation, the red lead energizes the hold coil and the
black lead is the common ground.
Current (amps) and resistance readings are shown in
Figure 4-5.
Resistance readings determine if the
solenoid windings are open or shorted. These readings
must be taken with fuel solenoid disconnected from
engine wiring harness.
Fuel Solenoid
Reading
Pull-In
Hold
Black-White (P) Leads
Black-Red Leads
50 Amps
1.0 Amps
0.12--0.26 Ohms
11-13 Ohms
Figure 4-5
Fuel Solenoid Readings
Summary of Contents for 10EOZ
Page 2: ......
Page 4: ...TP 6053 7 04 Table of Contents Notes ...
Page 10: ...TP 6053 7 04 VI Safety Precautions and Instructions Notes ...
Page 22: ...TP 6053 7 04 10 Section 2 Scheduled Maintenance Notes ...
Page 24: ...TP 6053 7 04 12 Section 3 Intake and Exhaust System Notes ...
Page 30: ...TP 6053 7 04 18 Section 4 Fuel System Notes ...
Page 44: ...TP 6053 7 04 32 Section 6 Controller Troubleshooting Notes ...
Page 62: ...TP 6053 7 04 50 Section 9 Generator Disassembly Reassembly Notes ...
Page 70: ...TP 6053 7 04 58 Section 10 Voltage Reconnection and Wiring Diagrams Notes ...
Page 79: ......