Section 3 Scheduled Maintenance
Waterline
1
2
3
7
8
9
19
10
11
12
13
14
15
16
17
18
21
20
6
5
4
TP-5586-3
22
1. Mounting base
2. Retaining cap
3. Reed valve assembly
4. Silencer vertical lift 1.2 m (4 ft.) max.
5. Exhaust catalyst assembly distance above waterline. If less
than 23 cm (9 in.), siphon break is required.
6. Siphon break distance above waterline 30.5 cm (1 ft.) min.
7. Siphon break
8. Exhaust catalyst assembly
9. Heat exchanger (locations vary by model)
10. Coolant recovery tank
11. Locate coolant recovery tank at same height as heat exchanger
12. Seawater strainer
13. Seacock
14. Intake strainer
15. Engine-driven seawater pump
16. Exhaust hose pitch 1.3 cm per 30.5 cm (0.5 in. per ft.) min.
17. Water lock (optional)
18. Silencer distance from exhaust catalyst assembly 3 m (10 ft.)
max.
19. Silencer (customer-supplied)
20. Exhaust hose pitch 1.3 cm per 30.5 cm (0.5 in. per ft.) min.
21. Exhaust outlet distance above waterline 10 cm (4 in.) min.
22. Seawater outlet
Figure 3-14
Siphon Break (Plastic “U” Type) Installation
Note:
Consult the installation manual for complete
explanation of dimensions and other installation
considerations.
Summary of Contents for 10EKD-Low CO
Page 4: ...TP 6591 10 13 4 Notes...
Page 8: ...TP 6591 10 13 8 Safety Precautions and Instructions Notes...
Page 12: ...TP 6591 10 13 12 Section 1 Service Views Notes...
Page 48: ...TP 6591 10 13 48 Notes...
Page 49: ...TP 6591 10 13 49 Notes...
Page 50: ...TP 6591 10 13 50 Notes...
Page 51: ...TP 6591 10 13 51 Notes...