Plumbing and Electrical Schematic

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY:

Electrical

1.  The electrical installation must comply with BS 7671 (commonly referred to as 

the IEE Wiring Regulations) and all relevant building regulations, or any particular 

regulation or practice specified by the local electricity supply company.

2.  Ensure that all circuit protection devices, switches and cabling is adequate 

for the rated current of the shower and that the rating of the electricity supply 

company fuse and the consumer unit are adequate for the additional demand.

3.  The shower 

must

 be earthed. Ensure any supplementary bonding complies 

with the relevant regulations.

4. 

This shower is intended to be permanently connected to the fixed electrical wiring 

of the mains system. A separate supply 

must

 be provided from the consumer 

unit to the shower.

5. 

DO NOT 

supply any other electrical equipment including extractor fans or pumps 

via this product.

6.  This shower must be provided with means for local disconnection that is 

incorporated into the fixed wiring in accordance with the relevant local wiring 

regulations. This 

must

 be a double pole switch, which has at least 3 mm contact 

separation in each pole. The switch can be a ceiling mounted pull-cord type within 

the shower room or a wall mounted switch fitted in the applicable zone area.

7. 

A 30mA Residual Current Device (RCD) must be incorporated into the electrical 

supply to this shower in accordance with wiring regulations.

8. 

DO NOT 

apply excessive force to the terminal block.

9. 

All electrical connections should be checked for tightness to prevent overheating 

before switching on the electrical supply.

10. 

DO NOT 

switch on the electrical supply until the plumbing has been completed 

and checked for leaks.

Summary of Contents for Mira Sprint

Page 1: ...1 Stop Start Mira Sprint 8 5 9 5 kW These instructions must be left with the user Installation and User Guide For SPARES ADVICE or REPAIRS Please call us on 0844 571 5000 UK Only...

Page 2: ...trols for power selection and for temperature flow adjustment A unique flow regulator stabilises any temperature changes caused by water pressure fluctuations which can result from taps being turned o...

Page 3: ...is properly insulated 5 DO NOT switch the shower on if there is a possibility that the water in the shower is frozen 6 DO NOT switch the shower on if water starts leaking from the shower case Isolate...

Page 4: ...boxes to familiarise yourself with the part names and to confirm that the parts are included 1 x Mira Sprint Electric Shower 3 x Wall Plugs 3 x Fixing Screws 1 x Installation and User Guide 1 x Guara...

Page 5: ...108 EC EMC Directive The Mira Sprint range of showers are high power appliances and are subject to conditional connection If the main electrical supply fuse is rated less than 80 Amps the local elect...

Page 6: ...CaCO3 Outlet Connection 1 2 BSP Male Electrical Variant Sprint 8 5 Sprint 9 5 Nominal Power at 230 V ac 7 8 kW 8 7 kW Nominal Power at 240 V ac 8 5 kW 9 5 kW Recommended MCB Rating 40 A 40 A Maximum S...

Page 7: ...on within the shower area and is fitted with a pressure relief valve It must be positioned over a water catchment area with the controls at a convenient height for the user 6 The shower must be fitted...

Page 8: ...ctions caused by excessive limescale formation are not covered by this shower s guarantee see back page for details 18 The installation must not cause the hose to be sharply kinked during normal use D...

Page 9: ...m A separate supply must be provided from the consumer unit to the shower 5 DO NOT supply any other electrical equipment including extractor fans or pumps via this product 6 This shower must be provid...

Page 10: ...let the connection to the inlet connector must still be made from the top or bottom through a bend Warning To avoid damage to the case when soldered fittings are used pre solder the pipework and fitti...

Page 11: ...Caution DO NOT twist the individual cable cores of the live and neutral conductors as this will prevent them from entering the terminal block 15 Fit an earth sleeve to the earth conductor Connect the...

Page 12: ...Cover Retaining Screws Do not fit the Mira Sprint to the wall and tile up to the case The Mira Sprint must be fitted on to a finished flat and even wall surface small pillars on the back of the case...

Page 13: ...ing from the bottom of the case 4 Turn the top control knob to the LOW position 5 Switch on the electrical supply at the double pole switch The power neon will provide a visual indication that the ele...

Page 14: ...this shows that the full power setting is operating correctly 10 Set the shower temperature by rotating the bottom knob as necessary Turn the knob clockwise for hotter water and anticlockwise for cool...

Page 15: ...all electrical appliances 8 DO NOT connect the outlet of the shower to any tap control valve trigger handset or showerhead other than those specified for use with this shower Only Kohler Mira recommen...

Page 16: ...er with less flow Anticlockwise rotation will give cooler water with more flow 6 To turn off the Mira Sprint press the stop button The appliance will continue to run for a few seconds before stopping...

Page 17: ...ing the thermal trip to operate and cut the power to the heater tank Showerhead sprayplate blocked Other outlets being used whilst showering causing water pressure to drop below minimum required to op...

Page 18: ...he cover of the appliance Only a competent tradesperson should remove the cover Key light illuminated A POWER indicator B LOW FLOW indicator Malfunction A B Cause Remedy No water or very low flow rate...

Page 19: ...switch is incorporated that cuts the power to the heater tank at too high a temperature Showerhead spray plate blocked Turn the temperature knob sufficiently anticlockwise to increase the water flow a...

Page 20: ...hority undertaker Check water supply static pressure Note Static pressure may fall below 0 2 bar when other appliances are operated e g dishwasher washing machine etc Power neon goes off when unit is...

Page 21: ...aning Many household cleaners contain abrasives and chemical substances and should not be used for cleaning plated or plastic fittings These finishes should be cleaned with a mild washing up detergent...

Page 22: ...off inlet water supply 1 Remove the three cover retaining screws the cover and the service tunnel 2 Remove the screws that hold the inlet clamp bracket in position and remove the clamp bracket 3 Loos...

Page 23: ...6 025 Service Tunnel 1563 527 Terminal Block A A B B B B B 1563 509 Switching Assembly 872 01 Microswitch N O 2 pin 1563 514 Low Flow Neon Assy 1563 515 Power On Neon Assy B 1563 516 Outlet Connector...

Page 24: ...product or consequential loss of any kind Damage or defects caused if the product is repaired or modified by persons not authorised by us or our appointed representative Routine maintenance or replac...

Reviews: