Plumbing
Variant
Sprint 8.5
Sprint 9.5
Minimum Dynamic Pressure
70 kPa
(0.7 bar)
70 kPa
(0.7 bar)
Maximum Static Pressure
1000 kPa (10 bar)
Minimum Static Pressure
20 kPa (0.2 bar)
Maximum Inlet Temperature
30°C
Minimum Inlet Temperature
2°C
Inlet Connection
1/2” BSP Male / 15 mm Compression Fitting
Maximum Water Hardness
200 ppm CaCO
3
Outlet Connection
1/2” BSP Male
Electrical
Variant
Sprint 8.5
Sprint 9.5
Nominal Power at 230 V ac
7.8 kW
8.7 kW
Nominal Power at 240 V ac
8.5 kW
9.5 kW
Recommended MCB Rating
40 A
40 A
Maximum Supply Cable Size
16 mm²
Recommended RCD Rating
30 mA tripping current
Recommended Isolator Switch
45 A double-pole with 3 mm contact separation
Appliance Sealing Rating
IP X4 - Suitable for installation in Zone 1
Maximum Ambient Temperature
30°C
Minimum Ambient Temperature
2°C
Dimensions
Height
342 mm
Width
204 mm
Depth
79 mm