4.1.4
Refit the burner assembly to the firebox by carefully pushing the bottom
of the burner back into position. Secure using the two screws into the
side frame of the firebox, and two screws into the base.
4.1.5
It is now necessary to refit the operating arm front section to the rear
section (reverse of procedure described above), when this is completed,
move the control lever fully downwards and check that the left hand
micro-switch operates the igniter and that the control valve spindle is
fully depressed. Move the control lever upwards to the “off” position
and check that the right hand (cut-off) micro-switch operates. Check
that the control lever operates smoothly and safely. Refit the logs and
glass panel.
4.2
Removing the Slide Control Gas Valve
4.2.1
Remove the burner as detailed in item 4.1
4.2.2
Remove the inlet pipe, burner pipe and pilot pipe from the slide valve.
4.2.3
Remove the thermocouple from the magnet unit.
4.2.4
Remove the 2 off valve retaining screws.
4.2.5
Replace valve as necessary then re-assemble in reverse order and
carry out a gas tightness test.
4.3
Removing the Oxy-Pilot
Note : Because this appliance is fitted with an atmosphere sensing ‘Oxy-
Pilot’ it is not possible to replace the thermocouple separately, because the
thermocouple position is factory set to a tight tolerance. Any replacement of
parts on the pilot requires a complete new pilot assembly.
4.3.1
Prepare work area (lay down dust sheets etc.)
4.3.2
Remove burner assembly as per section 4.1
4.3.3
Loosen the pilot nut and remove the two screws retaining the pilot
assembly. Remove wires / thermocouple from the valve.
4.3.4
Re-assemble in reverse order and carry out a gas tightness test.
4.4
Removal of the battery ignitor
4.4.1
Remove the burner assembly as per item 4.1
26