808
50ms MAX.
2ms MAX.
52ms MAX.
5ms MAX.
2ms MAX.
7ms MAX.
For sending @A
For sending @P, @PRE, @MODE
@P1 c/rl/f
※
c/rl/f : Enter key
OK c/rl/f
Sent
Received
@A c/rl/f
Sent
Received
@E
Function:
Displays L1 = Reference flow rate
−Δ
L, and
L2 for each channel.
Send example:
@E1 c/rl/f
Response example: 1.00 c/rl/f
←
L1 = Reference flow rate
−Δ
L
0.50 c/rl/f
←
L2
c/rl/f
Response example: NG c/rl/f
21: illegal type
@E1
1
:
1CH
2
:
2CH
3
:
3CH
4
:
4CH
@DIS
Function:
Switches off (Locks) the main unit LED.
Send example:
@DIS
﹈
1 c/rl/f
Response example: OK c/rl/f
Response example: NG c/rl/f
21: illegal type
@DIS
﹈
1
1: Not lighted
0: Lighted
@AS
Function:
Sets ON/OFF for autoscan function.
Send example:
@AS
﹈
1 c/rl/f
Response example: OK c/rl/f
Response example: NG c/rl/f
21: illegal type
@AS
﹈
1
1
:
ON
0
:
OFF
@PHL
Function:
Sets ON/OFF for peak hold function.
Send example:
@PHL
﹈
1 c/rl/f
Response example: OK c/rl/f
Response example: NG c/rl/f
21: illegal type
@PHL
﹈
1
1
:
ON
0
:
OFF
@BHL
Function:
Sets ON/OFF for bottom hold function.
Send example:
@BHL
﹈
1 c/rl/f
Response example: OK c/rl/f
Response example: NG c/rl/f
21: illegal type
@BHL
﹈
1
1
:
ON
0
:
OFF
MULTI-CHANNEL FLOW RATE SENSOR CONTROLLERS