background image

Dimensions 

(mm)

Pulse blow unit application example

Air gun ionizer can be used as a pulse blow gun simply by installing 

a pulse blow unit.

Pulse blow unit

PAU-7W

IN Port size :Rc1/4

Jack size: φ6

・N

on-oil specifi cation (fl uorine-based  

   quick-drying lubricant is applied)

Operating  air pressure range: 0.35 to 

   0.7MPa

Pulse blow unit (low pressure type) 

PAU-8W

IN Port size :Rc1/4

Jack size: φ6

・N

on-oil specifi cation (fl uorine-based  

   quick-drying lubricant is applied)

Operating  air pressure range: 0.2 to 

   0.5MPa

※ 1: 

Contact our sales representative for DTY-ELG21 performance when a pulse blow unit is

         installed.

※ 2: Refer to the Pulse Blow Series CatalogNo:BK-P393 for detailed specifi cations of a

       pulse blow unit.

※ 3: Pulse blow unit Mass 66 g.

DTY-ELG21

13.5

25

34

AC adapter

300±50

12.5

20

10

Power indicator 

LED (green)

Error indicator 

LED (red)

Operation lever

Nozzle

φ6 quick fitting

Power cable

(140.1)

φ2

2

52

(3000)

24.5

φ20

(

Suspension bracket 90°

)

Suspension

bracket

72

(135.8)

30

24.5

φ2

2

Ion air outlet

Replacement nozzle

Main unit

2

OUT

IN

OUT

IN

When a pulse blow unit is installed

Summary of Contents for DTY-ELG21

Page 1: ...er Power indicator LED green Alarm Alarm indicator LED red Outer dimensions mm 164 6 L 25 W 135 8 H not including protrusions Mass g 200 without cables Ion balance 1 V 15 Ozone generation amount 2 ppm 0 04 or less Medium 3 Air clean air water vapor and oil removed Operating air pressure rangeMPa 0 05 0 6 Operating Environment Indoors 0 to 40 C 65 or less non condensation Material Body PBT Nozzle P...

Page 2: ...ing the nozzle or take off the nozzle for the maintenance of the discharge needle tighten the nozzle securely by hand without using a tool Static charge removal characteristics Flow characteristics 0 0 1 0 2 0 3 0 4 0 5 0 6 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 Air pressure MPa Static charge removing time sec Measuring distance 50mm Static charge removing time for supplied air pressure 0 6 0 5 0 4 0 3 0 2...

Page 3: ...nt is applied Operating air pressure range 0 2 to 0 5MPa 1 Contact our sales representative for DTY ELG21 performance when a pulse blow unit is installed 2 Refer to the Pulse Blow Series CatalogNo BK P393 for detailed specifications of a pulse blow unit 3 Pulse blow unit Mass 66 g DTY ELG21 13 5 25 34 AC adapter 300 50 12 5 20 10 Power indicator LED green Error indicator LED red Operation lever Noz...

Page 4: ...GANEI CORP shall void this warranty This warranty covers only such items supplied by KOGANEI CORP The products of other manufacturers are covered only by such warranties made by those original manufacturers even though such items may have been included as the components The specifications are subject to change without notice Warranty Period Koganei Responsibility Limitations 06 20 KOGANEI CORP PRI...