background image

Main unit

DTY-ELG21

Order codes

AC adapter (accessory) 

Rating 

input    :  AC100

240V

 

    50/60Hz 0.58A

Output :  DC24V 1A

Cable length: 300 mm

DTRY-ZEM-G11

NOTE : For ELG11/21 air gun type only

●Options (sold separately)

Replacement tungsten discharge needle (unit: 5 per set)

Special tool for replacing discharge needle
NOTE: Only bits are for sale.

AC Adapter (300mm)

Replacement nozzle

DTRY-ELB21

DTY-ZN1-G21

6.35

9

22

φ4.5

Shape of jig for replaceable bit

Main unit 

Cable length :3000 mm

Replacement of discharge needle

When replacing the discharging needle, use the dedicated tool DTRY-ELB21 in combination with a torque driver.The dedicated tool is designed not 

to damage the discharge needle or the threaded part of the main body. Replacing with another tool may cause damage to the discharge needle and 

main body, etc.The tightening torque for replacement should be 15 to 20N·cm.If the discharge needle is replaced without using the dedicated tool 

and the discharge needle, main body, etc. are damaged, the warranty will not cover.

NOTE: When replacing the nozzle or take off the nozzle for the maintenance of the discharge needle, tighten the nozzle securely by hand without

            using a tool.

Static charge removal characteristics

Flow characteristics

0

0.1

0.2

0.3

0.4

0.5

0.6

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

Air pressure [MPa]

Static charge removing time [sec]

Measuring distance :50mm

Static charge removing time for supplied air pressure

0.6

0.5

0.4

0.3

0.2

0.1

0

0

100

200

300

400

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

供給エア圧力(MPa)

除電時間

(秒)

測定距離:50mm

Air pressure [MPa]

Flow rate [L/min] (ANR)

DTRY-ZPS-G11

Note 1:Measured using a 150 mm, 20pF charged plate monitor.

Note 2:The static charge removing time is the decay time from 

            ± 1000 V to ± 100 V.

Note 3:The above data are actual measurement valve and are   

             not guaranteed. 

※  

Be sure to read the safety precautions (common to the 

ionizers) and handling instructions and precautions 

(common precautions) on the website prior to using 

the product.

※  

DReplacement nozzle 

     only for DTY-ELG21

1

Do not point the tip of the nozzle at a person.

Use safety glasses and earplugs because blowing air could blow 

objects into peopleʼs eyes or cause hearing loss.

Warning

NOTE: The above data are actual measurements and are not guaranteed.

Summary of Contents for DTY-ELG21

Page 1: ...er Power indicator LED green Alarm Alarm indicator LED red Outer dimensions mm 164 6 L 25 W 135 8 H not including protrusions Mass g 200 without cables Ion balance 1 V 15 Ozone generation amount 2 ppm 0 04 or less Medium 3 Air clean air water vapor and oil removed Operating air pressure rangeMPa 0 05 0 6 Operating Environment Indoors 0 to 40 C 65 or less non condensation Material Body PBT Nozzle P...

Page 2: ...ing the nozzle or take off the nozzle for the maintenance of the discharge needle tighten the nozzle securely by hand without using a tool Static charge removal characteristics Flow characteristics 0 0 1 0 2 0 3 0 4 0 5 0 6 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 Air pressure MPa Static charge removing time sec Measuring distance 50mm Static charge removing time for supplied air pressure 0 6 0 5 0 4 0 3 0 2...

Page 3: ...nt is applied Operating air pressure range 0 2 to 0 5MPa 1 Contact our sales representative for DTY ELG21 performance when a pulse blow unit is installed 2 Refer to the Pulse Blow Series CatalogNo BK P393 for detailed specifications of a pulse blow unit 3 Pulse blow unit Mass 66 g DTY ELG21 13 5 25 34 AC adapter 300 50 12 5 20 10 Power indicator LED green Error indicator LED red Operation lever Noz...

Page 4: ...GANEI CORP shall void this warranty This warranty covers only such items supplied by KOGANEI CORP The products of other manufacturers are covered only by such warranties made by those original manufacturers even though such items may have been included as the components The specifications are subject to change without notice Warranty Period Koganei Responsibility Limitations 06 20 KOGANEI CORP PRI...

Reviews: