u
Model
Item
Power supply
Note 1
Consumption current
mA
Operating high-voltage power supply
Output voltage
kV
Power safety circuit
Note 2
Abnormal output circuit
Outer dimensions
mm
Mass
g
Ion balance
V
Note 3
Ozone generation amount
ppm
Note 4
Supply air flow rate
R
/min(ANR)
Operating air pressure range
MPa
{
kgf/cm
2
}
Operating environmental temperature
℃
Accessories
24 VDC ± 5%
Approx. 100
Miniaturized AC high-voltage high-frequency type
Approx. 2
Alarm signal output when abnormality in high-voltage section. (When this unit is used, supply air continuously.)
Open collector 24 VDC (10 mA, max.)
92 (L) × 30 (W) × 54 (H) (Main unit only)
92 (L) × 62 (W) × 54 (H) (Main unit only)
190 (Main unit only)
300 (Main unit only)
±15
0.037 or less
100 (With DTRY-NZR01 nozzle and 0.15 MPa air at primary side)
0.02 〜 0.25
{
0.2 〜 2.5
}
(With DTRY-NZR01 nozzle)
0.02 〜 0.12
{
0.2 〜 1.2
}
(With DTRY-NZR02 nozzle)
0.02 〜 0.12
{
0.2 〜 1.2
}
(With DTRY-NZR03 nozzle)
0.05 〜 0.25
{
0.5 〜 2.5
}
(With DTRY-NZR04-08 nozzle)
0〜 40 indoors
1 power and signal cable (2 m) and 1 ground wire (2 m).
DTRY-ELB01
(Main Unit for a Single Nozzle)
DTRY-ELB02
(Main Unit for Twin Nozzles)
Item
Model
Power supply
Operating high-voltage power supply
Consumption current
mA
Output voltage
kV
Indicator lamp
Power safety circuit
Outer dimensions
mm
Mass
g
Ion balance
V
Ozone generation amount
ppm
m
3
/min
Fan capacity
Operating environmental temperature
℃
Accessories
Power supply
Abnormality
Max. flow rate
Adjusting
12 〜 24 VDC ± 10%
Miniaturized AC high voltage high-frequency type
300 (with 12 VDC power supply) / 150 (with 24 VDC power supply)
Approx. 2
POWER LED (green) on the top of the main unit turns on, while the power is supplied
ALARM LED (red) on the top of the main unit turns on, when abnormality occurs.
Provides an abnormal contact signal and alarm signal in the case of abnormality in high voltage section. (ALARM LED on the top of the main unit turns on)
Provides an abnormal contact signal and alarm signal, when a blower fan stops. (ALARM LED on the top of the main unit turns on)
46 (L) × 67 (W) × 81 (H) (Main unit only)
320 (Main unit only)
±10
0.04 or less
0.225
High-Low 2-step selection
0〜 40 indoors
1 power and signal cable (2 m) and 1 in-line connection cable (2 m).
DTRY-ELF01
Item
Model
Power supply
Consumption current
mA
Outer dimensions
mm
Mass
g
Media
Max. flow rate
R
/min(ANR)
Operating pressure adjusting range MPa
{
kgf/cm
2
}
Proof pressure
MPa
{
kgf/cm
2
}
μm
Filter capacity
Operating environmental temperature
℃
Accessories
Collected particle size
Collection efficiency
%
24 VDC ± 5%
410
222 (L) × 60 (W) × 135 (H) (Main unit only)
830 (Main unit only)
Air
100 ( 0.5 MPa at primary-side pressure and 0.15 MPa at secondary-side pressure)
0.02 〜 0.3
{
0.2 〜 3.0
}
0.3
{
3.0
}
0.01
99.99
5〜 45 indoors
1 power and signal cable (1.5 m).
DTRY-ELC11
Specifications
■
Blow Type
■
Fan Type
■
Controller (for the blow type)
Notes 1: Power supply is common with ELB01 and ELB02.
2: To use the power safety circuit correctly, recommend to use the controller(
DTRY-ELC11
).
3: Ion balance is measured by using DTRY-NZR01.
4: Ozone generation amount is measured by using DTRY-NZR01 at a 50mm position from the outlet.