!4
Turbo-flow fan type
●
DTRY-ELT11
Power and signal connector
(
molex#5557-04R
)
21.5
43
Flow rate adjusting plate
(provided part)
Power and signal cable : VCTF-0.3 mm, 2
×
4 wires
JIS-C. 3306
10
5
2000
Fan guard
4-M4
×
0.7: depth 5 (both sides)
(mounting hole)
Ground terminal
Connector (male)
(
molex#5569-04A
)
Power indication LED
(Green)
Abnormality indication LED
(Red)
102
37
26
18
12
102
70
16
#4
#3
#2
#1
#1 [white] :Abnormal output
#2 [black] :Output GND
#3 [red]
:Input power DC+24V
#4 [green] :Power GND
Pin location of molex #5557-04R (female)
Power and signal cable (Accessory)
●
Input power: DC+24V
●
Connector pin location and lead wire colors:
View from A
A
Flow direction adjusting plate (4 pcs.)
Note
Notes:
After mounting the turbo flow fan type by using
the optional bracket (
DTRY-ELQO1
), the flow
direction adjusting plate allows fine adjustment of
the direction of the flow by bending it. However,
repeated bending may dreak the plate. Number of
bending of the plate should be kept to a minimum
(around several times).
Summary of Contents for DTRY-ELB01
Page 18: ... 7 memo memo ...
Page 19: ...和文カタログ No C2152 w ...