MJ400252C1
- 9 -
6.
How to Use
6-1 Warming up
Warm up the equipment for at least 15 minutes after it was powered on.
6-2 Operating procedure
・
Operation panel
・
Indicator
Indicates an instantaneous flow rate or integrated flow rate.
During setting, the mode No. or set value is shown here.
・
Alarm lamps
When the alarm output 1 is on,
“
AL1
”
lights and when the alarm output 2 is on,
“
AL2
”
lights.
・
Indicator lamps
When an instantaneous flow rate is being indicated,
“
IF
”
lights and when an integrated flow
rate is being indicated,
“
TF
”
lights.
・
Shift key [
<
]
Measurement: Switches over the indication of flow rates between the instantaneous flow rate
and the integrated flow rate.
Setting: Moves the flashing digit to left.
Returns to the flow rate indication when the mode No. is being indicated.
・
Up key [
∧
]
Measurement: Not used.
Setting: Increments the value of the flashing digit.
・
Down key [
∨
]
Measurement: Not used.
Setting: Decrements the value of the flashing digit.
・
ENT key
Measurement: Not used.
Setting: Accepts an entered value.
ENT key
Up key
Shift key
Indicator
Down key
Alarm
lamps
Indicator
lamps