K430X2 Dual Twin Foaming Characteristics Test Bath 

Operation and Instruction Manual 

 

K430X2-Manual

    

 

-

17-

 

9  Troubleshooting 

 

WARNING:

 

Troubleshooting  procedures  involve 

working  with  high  voltages  and/or  temperatures 
which  may  result  in  personal  injury  or  death,  and 
should  only  be  performed  by  trained  personnel. 
Please  do  not  hesitate  to  contact  Koehler  for 
assistance. 
 

9.1  Unit does not power up 

 

 

Establish  that  the  socket  outlet  is  providing 
proper and adequate voltage. 

 

Check  if  Overpower  Protection  circuitry 
located  directly  behind  the  temperature 
controller  inside  the  front  tray  has  been 
activated. 

 

Check if line switch is in the 

ON 

position. 

 

If  problem  persists,  please  call  the  Koehler 
technical service department for assistance. 

 

9.2  Unit  is  on  and  keeps  resetting  into 

start up routine 

 

 

For  220V  units,  make  sure  that  the  socket 
outlet is greater than 215V. 

 

Check if there is a steady and reliable power 
source. 

 

Make  sure  the  connector  plug  on  the  rear 
panel is firmly plugged in. 

 

9.3  Unit is on but bath does not heat up 

 

 

Make  sure  that  the  actual  temperature 
reading  is  not  higher  than  the  set-point 
temperature. 

 

Determine  if  the  temperature  controller  is 
properly  calibrated  by  comparison  to  an 
ASTM standard thermometer. 

 

Determine if the Overtemperature Protection 
(OTP) circuitry as been activated. 

 

9.4  Bath  heats  up  but  temperature  does 

not stabilize 

 

 

Make  sure  there  are  no  drafts  from  open 
doors,  windows,  or  environmental  control 
vents in the vicinity of the bath. 

 

If  the  set  temperature  is  close  to  ambient, 
then  you  may  need  to  circulate  cold  water 
through  the  coils  in  order  to  achieve  proper 
temperature stability. 

 

10  Service

 

 

Under  normal  operating  conditions  and  with 

routine  maintenance,  the  K430X2  Dual  Twin 
Foaming  Characteristics  Test  Bath  should  not 
require  service.  Any  service  problem  can  be 
quickly resolved by contacting Koehler’s technical 
service  department  either  by  letter,  phone, fax,  or 
email.  In  order  to  assure  the  fastest  possible 
service,  please  provide  us  with  the  following 
information. 

 

Model Number:   

 

 

 

 

Serial Number:   

 

 

 

 

Date of Shipment:   

 

 

 

          

11  Storage

 

 

This  laboratory  test  instrument  is  equipped  with 

electrical components. Storage facilities should be 
consistent  with  an  indoor  laboratory  environment. 
This testing equipment should not be subjected to 
extremes of temperature and/or moisture. 

 
This equipment  was shipped from the factory  in 

a  corrugated  cardboard  container.  If  long  term 
storage is anticipated, re-packing the instrument in 
a  water-resistant  container  is  recommended  to 
ensure equipment safety and longevity. 

 

12  Warranty

 

 

We, at Koehler, would like to thank you for your 

equipment  purchase,  which  is  protected  by  the 
following  warranty.  If  within  one  (1)  year  from  the 
date  of  receipt,  but  no  longer  than  fifteen  (15) 
months  from  the  date  of  shipment,  Koehler 
equipment  fails  to  perform  properly  because  of 
defects  in  materials  or  workmanship,  Koehler 
Instrument Company, Inc. will repair or, at its sole 
discretion,  replace  the  equipment  without  charge 
F.O.B. its plant, provided the equipment has been 
properly  installed,  operated,  and  maintained. 
Koehler  Instrument  Company  must  be  advised  in 
writing of the malfunction and authorize the return 
of  the  product  to  the  factory.  The  sole 
responsibility of Koehler Instrument Company and 
the  purchaser’s  exclusive  remedy  for  any  claim 
arising  out  of  the  purchase  of  any  product  is  the 
repair  or  replacement  of  the  product.  In  no  event 
shall  the  cost  of  the  purchaser’s  remedy  exceed 
the  purchase  price,  nor  shall  Koehler  Instrument 
Company  be  liable  for  any  special,  indirect, 
incidental,  consequential,  or  exemplary  damages. 
KOEHLER 

INSTRUMENT 

COMPANY, 

INC. 

Summary of Contents for K430X2

Page 1: ...ohemia New York 11716 1796 USA Toll Free 1 800 878 9070 US only Tel 1 631 589 3800 Fax 1 631 589 3815 http www koehlerinstrument com e mail info koehlerinstrument com Petroleum Testing Analysis Instrumentation Custom Design Manufacturing K430X2 Dual Twin Foaming Characteristics Test Apparatus ...

Page 2: ......

Page 3: ...with the applicable standards set forth in this certification Specifications ASTM D892 IP 146 DIN 51566 FTM 791 3211 FTM 791 3213 NF T 60 129 This unit is tested before it leaves the factory to ensure total functionality and compliance to the above specifications and ASTM standards Test and inspection records are on file for verification Jesse Kelly Application Engineer Koehler Instrument Company ...

Page 4: ......

Page 5: ...K430X2 Dual Twin Foaming Characteristics Test Bath Operation and Instruction Manual K430X2 Manual 1 ...

Page 6: ...K430X2 Dual Twin Foaming Characteristics Test Bath Operation and Instruction Manual K430X2 Manual 2 ...

Page 7: ...asic information on subsequent processing or recycling prior to disposal of the equipment http www dpa system dk en WEEE Products Private or professional use Responsibility for Registration and Annual Reporting Koehler will not sell directly to end users in the EU and so has no responsibility to register within each EU state and to make annual reports Koehler declares that this responsibility is b...

Page 8: ...eparately collected WEEE Mercury containing components such as switches or backlighting lamps compact fluorescent lamps CFL Batteries Printed circuit boards if the surface of the printed circuit board is greater than 10 square centimeters about 4 sq in Toner cartridges liquid and pasty as well as color toner Chlorofluorocarbons CFC hydrochlorofluorocarbons HCFC or hydrofluorocarbons HFC hydrocarbo...

Page 9: ... Flowmeter Setup and Operation 11 4 3 Flowmeter Calibration Data 11 4 4 Temperature Controller Operation 11 5 Operation 13 5 1 Bath 13 5 2 Power 13 5 3 Preparation of Glassware and Tubing 13 6 Safety Features 14 6 1 Over Temperature Protection 14 6 2 Over Power Protection 14 7 Maintenance 14 7 1 Routine Maintenance 14 7 2 Bath Cleaning 14 7 3 Replacement Parts 15 8 Wiring Diagrams 16 8 1 Unit Wiri...

Page 10: ...K430X2 Dual Twin Foaming Characteristics Test Bath Operation and Instruction Manual K430X2 Manual 6 12 Warranty 17 13 Returned Goods Policy 18 Notes 19 ...

Page 11: ...specialists who are experienced in both petroleum products testing and instrument service to better understand your requirements and provide you with the best solutions You can depend on Koehler for a full range of accurate and reliable instrumentation as well as support for your laboratory testing programs Please do not hesitate to contact us at any time with your inquiries about equipment tests ...

Page 12: ... and Replacement Parts Any modification or alteration of this equipment from that of factory specifications is not recommended voids the manufacturer warranty product safety performance specifications and or certifications whether specified or implied and may result in personal injury and or property loss Replacement parts must be O E M exact replacement equipment Over Temperature Protection This ...

Page 13: ...rom box to cart and from cart to bench Individuals must lift in accordance to proper technique See Figure below 7 Lift instrument from cart and place on bench 8 Ensure that all parts listed on the packing list are present Inspect the unit and all accessories for damage If any damage is found keep all packing materials and immediately report the damage to the carrier We will assist you with your cl...

Page 14: ...1 Main Instrument Controls Figure 1 Main Instrument Descriptions 1 Power Switch This switch controls the power to motor and heater temperature controller of its corresponding side When the power switch is in the ON position the digital temperature controller and the stirrer are powered on 2 Temperature Controller The temperature controller regulates the bath temperature its corresponding bath Refe...

Page 15: ...the duration specified in the test procedure and disconnect the tygon tubing from the flowmeter outlet when the aeration period as elapsed 4 3 Flowmeter Calibration Data K43002 0 12 Air Flow Rate 94 mL min Float Material Sapphire Float Density 3 98 g ml Metered Fluid Air Minimum Flow 16 4 ml min Maximum Flow 159 0 ml min Tolerance 2 F S Scale Reading mm Flowrate ml min 65 159 0 60 139 0 55 121 2 5...

Page 16: ...is a value observed in the upper red LED display add it to the calculated difference obtained in the previous step This is the offset value c Press the Program Key The lower green display will flash Use the up or down keys to adjust to the new calibration offset value on the upper red display calculated in the previous step When the value has been entered the controller will automatically store th...

Page 17: ...s that will decompose or volatilize producing flammable vapors below the maximum instrument operating temperature 25 C NOTE Coloration of the Mineral or Silicon Bath Oil is an indication that the Medium must be changed See Draining instructions in section 7 3 of this document When a decision is made to discard this material dispose of this material and its container to a hazardous of special waste...

Page 18: ...e servicing to avoid exposure to high voltages and or temperatures which may result in personal injury or death If you have any questions about maintaining your equipment then please do not hesitate to contact the Koehler technical service department 7 1 Routine Maintenance The K430X2 Dual Twin Foaming Test Bath requires little routine maintenance to provide many years of continuous service Howeve...

Page 19: ...0Hz 7A 278 001 002 Fuse 1A Slo Blo 5 X 20 mm 332 001 003 12 x 18 Borosilicate Bath Jar K23425 03000 18 Safety Shield K23700 03014A Motor 230V 50 60HZ 1 15HP K430 0 13 Air Outlet Elbow Tube K430 0 8 Rubber Stopper K430 3A Air Inlet Delivery Tube without diffuser K43002 0 12 Low Flowmeter K43002 0 13 Test Tube Rack K43002 0 15 Locking Post Assembly K43012 1000ml Cylinder w Ring K43002 0 9 Hot Bath O...

Page 20: ...K430X2 Dual Twin Foaming Characteristics Test Bath Operation and Instruction Manual K430X2 Manual 16 8 Wiring Diagrams 8 1 Unit Wiring ...

Page 21: ... Dual Twin Foaming Characteristics Test Bath should not require service Any service problem can be quickly resolved by contacting Koehler s technical service department either by letter phone fax or email In order to assure the fastest possible service please provide us with the following information Model Number Serial Number Date of Shipment 11 Storage This laboratory test instrument is equipped...

Page 22: ...er the item s to be returned and the reason for the return You will be issued a Returned Authorization RA number which must be prominently displayed on the shipping container when you return the material to our plant Shipping containers without an RA number prominently displayed with will be returned to the sender Goods must be returned freight prepaid Returns will be subject to a restocking charg...

Page 23: ...K430X2 Dual Twin Foaming Characteristics Test Bath Operation and Instruction Manual K430X2 Manual 19 Notes ...

Page 24: ...K430X2 Dual Twin Foaming Characteristics Test Bath Operation and Instruction Manual K430X2 Manual 20 Notes ...

Reviews: