Koehler K39400 Operation And Instruction Manual Download Page 6

K394XX Water Separability Tester 

Operation and Instruction Manual 

 
 

K394XX-Manual

    

 

-

2-

 

 

this.  All Koehler equipment has been placed on the market since 13th August 2005  and so Koehler is 
defined as a "new WEEE producer". As such we must provide information on refurbishment, treatment, 
and re-use. 
 
Our instrument manual will include this compliance statement and indicate that any collection of materials 
will be handled by their authorized distributor. In the event that the distributor is unreachable or is no 
longer a distributor for Koehler Instrument, Co., other arrangements may be made including accepting the 
materials directly. 
 
Recycling is free of charge. Shipping is the responsibility of the end users. Whether shipping to a 
distributor or to Koehler directly, safe, properly declared, and labeled packaging and shipping expenses 
are the sole responsibility of the end user. 
 

WEEE Marking 

 
 
 
 
 
 
 
 
Since Koehler products are subject to the WEEE Directive we must display the WEEE symbol shown 
above in accordance with European Standard EN 50419 on the equipment. It must be indelible, at least 
5mm in height, and clearly legible. If the equipment is too small the mark must be in the product literature, 
guarantee certificate, or on the packaging. Rules on marking are established in section 49 of the WEEE 
Order. 
 
Koehler Instrument Company, Inc. 
c/o RECYCLING 
1595 Sycamore, Ave. 
Bohemia, NY 11716 
 
As a minimum the following substances, preparations and components have to be removed from any 
separately collected WEEE: 
- Mercury containing components, such as switches or backlighting lamps (compact fluorescent lamps, 
CFL), 
- Batteries 
- Printed circuit boards if the surface of the printed circuit board is greater than 10 square centimeters 
(about 4 sq in.), 
- Toner cartridges, liquid and pasty, as well as color toner, 
- Chlorofluorocarbons (CFC), hydrochlorofluorocarbons (HCFC) or hydrofluorocarbons (HFC), 
hydrocarbons (HC) 
- Liquid crystal displays (together with their casing where appropriate) of a surface greater than 100 
square centimeters and all those back-lighted with gas discharge lamps, 
- External electric cables 
- Components containing refractory ceramic fibers as described in Commission Directive 97/69/EC of 5 
December 1997 adapting to technical progress Council Directive 67/548/EEC relating to the classification, 
packaging and labeling of dangerous substances (2), 
- Electrolyte capacitors containing substances of concern (height > 25 mm, diameter > 25 mm or 
proportionately similar volume) 
 
2. The following components of WEEE that is separately collected have to be treated as indicated: 
- Equipment containing gases that are ozone depleting or have a global warming potential (GWP) above 
15, such as those contained in foams and refrigeration circuits: the gases must be properly extracted and 
properly treated. Ozone-depleting gases must be treated in accordance with Regulation (EC) No 
2037/2000 of the European Parliament and of the Council of 29 June 2000 on substances that deplete 
the ozone layer (4). 

Summary of Contents for K39400

Page 1: ...venue Bohemia New York 11716 1796 USA Toll Free 1 800 878 9070 US only Tel 1 631 589 3800 Fax 1 631 589 3815 http www koehlerinstrument com e mail info koehlerinstrument com Petroleum Testing Analysis...

Page 2: ......

Page 3: ...andards set forth in this certification Specifications ASTM D1401 ASTM D6074 ASTM D6158 ISO 6614 DIN 51599 FTM 791 3201 NF T 60 125 This unit is tested before it leaves the factory to ensure total fun...

Page 4: ......

Page 5: ...tement is given cataloging the items that require separation from the equipment along with basic information on subsequent processing or recycling prior to disposal of the equipment http www dpa syste...

Page 6: ...minimum the following substances preparations and components have to be removed from any separately collected WEEE Mercury containing components such as switches or backlighting lamps compact fluores...

Page 7: ...packing 5 3 3 Setup 6 4 Descriptions 7 4 1 Description of Instrument Controls 7 4 2 Temperature Controller Operation 7 5 Operation 9 5 1 Bath 9 5 2 Power 9 5 4 Test Control Panel Operation 11 6 Safety...

Page 8: ...ducts are backed by our staff of technically knowledgeable trained specialists who are experienced in both petroleum products testing and instrument service to better understand your requirements and...

Page 9: ...Over temperature Protection This unit is equipped with over temperature Protection OTP circuitry to prevent overheating The unit will automatically interrupt power whether equipment malfunction or op...

Page 10: ...red glass front panel jar pose a hazard to personnel Impacts to these during normal operation can shatter the glass components releasing the bath fluid posing thermal burn hazards and slipping hazards...

Page 11: ...g Bath Stainless Steel Bath with clear tempered glass front viewing window for stabilizing the bath temperature to desired setting within 0 05 C 6 Cylinder Ports The test cylinder is placed into the h...

Page 12: ...ture Calculate the difference between the measuring device and the Process value displayed on the controller b Press the program key two times until PCt is displayed in the lower green LED display Pre...

Page 13: ...ium must be changed See Draining instructions in section 7 3 of this document When a decision is made to discard this material dispose of this material and its container to a hazardous of special wast...

Page 14: ...e rail Otherwise shaft may get bent or damaged and will no longer be useful for operation 6 Lift the Stirrer shaft up then move the head assembly left or right until stirrer paddle is over the sample...

Page 15: ...op button may be used to interrupt the 10 second audible alarm 11 At the end of the stirring period please follow the appropriate test method such as those listed in section 1 2 for determining the wa...

Page 16: ...atus is equipped with Over temperature Protection OTP circuitry which prevents the unit from exceeding unsafe operating temperatures If the unit cannot maintain the set point temperature and begins to...

Page 17: ...ior with organic chemicals such as Acetone Toluene Hexane etc For more difficult cleaning of finished surfaces a dilute solution or isopropanol in water may be used It is not recommended that more agg...

Page 18: ...K394XX Water Separability Tester Operation and Instruction Manual K394XX Manual 14 8 Wiring Diagrams 8 1 K39400 Unit Wiring...

Page 19: ...K394XX Water Separability Tester Operation and Instruction Manual K394XX Manual 15...

Page 20: ...K394XX Water Separability Tester Operation and Instruction Manual K394XX Manual 16...

Page 21: ...K394XX Water Separability Tester Operation and Instruction Manual K394XX Manual 17 8 2 K39496 Unit Wiring...

Page 22: ...K394XX Water Separability Tester Operation and Instruction Manual K394XX Manual 18...

Page 23: ...K394XX Water Separability Tester Operation and Instruction Manual K394XX Manual 19...

Page 24: ...eturn of the product to the factory The sole responsibility of Koehler Instrument Company and the purchaser s exclusive remedy for any claim arising out of the purchase of any product is the repair or...

Page 25: ...K394XX Water Separability Tester Operation and Instruction Manual K394XX Manual 21 Notes...

Page 26: ...K394XX Water Separability Tester Operation and Instruction Manual K394XX Manual 22 Notes...

Reviews: