30
9.
Circuit Breakers:
Each of outlets on the electrical panel is pro-
tected with a circuit breaker to prevent over-
loading the circuit. If a breaker trips, reduce
the load before re-setting the breaker.
• The two 120 volt 20 amp outlets are each
protected by a 20 amp pop up circuit
breaker. The KD series have the added
feature of GFCI (5-20R) protected outlets.
• The 120 volt 30 amp (L5-30) receptacle
is protected by a 30 amp breaker. If this
breaker trips then the 20 amp circuit as
well as the 30 amp circuit will be off.
• The 120/240 volt (14-30R) receptacle is
protected by a 30 amp breaker in the
KD7300D and 20 amp in the KD5000D,
which also serves as the main off/on
switch. If this breaker trips all the circuits
will be off.
10.
Operating Hints:
• Position frame on a level area to minimize
the chance of spilling fuel and maximize
the fuel capacity of the tank. Spilled fuel
can be ignited by a spark from the electrical
power system.
• Do not refuel while the engine is running. wait
until the unit has cooled before refuelling.
• Keep the working area neat and clean to pre-
vent slipping and tripping. Prevent accidents
at the work site.
• Always keep the generator and connections
dry, do not let water pool around the generator
or connections to prevent potential electrocu-
tion hazard.
• Position the generator under cover to protect
it from rain or bad weather.
• Do not operate when the ambient tempera-
ture exceeds 100° F (39° C) to
prevent overheating.
• Do not cover the unit during opera-
tion to prevent overheating.
IMPORTANT
A circuit breaker that trips
repeatedly indicates a
problem.
KD5000D
30 Amp
(KD7300D)
20 Amp
(KD5000D)
30 Amp
20 Amp
Generator in optimum
working condition