Chapter 3 Installation
MDS-1100R Series
3-24
0092642260-01
16) Connect connector P2 to J2
[PCB 62-110X].
P2 -> J2
PCB: E62-110X
17) Hook the P2 to J2 to the clamp.
P2 -> J2
Clamp
19) Connect connectors P3 and P4 to J3 and J4 [PCB
E61-120X]
Fix the two fixing bolts.
(Tool: Wrench 13mm)
P3 -> J3
PCB: E61-120X
Bolt
Bolt
18) Insert the TR unit in the
scanner unit
housing.
TR unit