3) Connect the Transducer to the junction box (JB-34).
• In case of TD-284A and TD-504F
Refer to Figure 1.44 and connect the cable to the junction box (JB-34).
Fig. 1.44 Connection between junction box and transducer
Connection of the resonance capacitor (Be sure transducer cable is connected to avoid
damaging the system with capacitor only.)
•TD-284A
Low frequency side
•
TD-504F (Connect to the High frequency side whenTD-284A is connected.)
High frequency side
0.1μF
0.047μF
Fig. 1.45 Connection between junction box and capacitor
CW-836-3M
Black
Shield
White
Green
Shield
Red
Low frequency
TD-284A
High frequency
TD-504F
Black
Shield
White
Black
Shield
White
Caution: Do not transmit with capacitor only as internal
circuit may be damaged.