![Koden CVS-875D Installation Manual Download Page 64](http://html.mh-extra.com/html/koden/cvs-875d/cvs-875d_installation-manual_1984764064.webp)
Chapter 1 Installation
CVS-875D/877D
1-42
0092607072-01
Connection table of transducer
*For low frequency, there are two combinations of cable colors, (yellow and black) and
(blue/white and black/white). Connect the wires to the corresponding pin number.
CVS-875D/877D
Junction box
(JB-34)
Transducer
No.
Connection to:
Pin
No.
Signal name at
connection to:
Color of cable
Remarks
J7
1
Red/TD1H
(high frequency transducer)
1
TD1H
Blue
High frequency
4
Green/TD2H
(high frequency transducer)
2
TD2H
Black
3
Shield
3
GND
Shield
-
-
4
-
-
-
2
White/TD1L
(low frequency transducer)
5
TD1L
Yellow
(Blue/ white)*
Low frequency
5
Black/TD2L
(low frequency transducer)
6
TD2L
Black
(Black/White)*
3
-
7
GND
Shield
-
8
-
-
-
-
-
-
9
-
-
-
J6
4
Shield
10
Shield
Shield (In)
Shield
8
Black / XID GND
11
XID GND
Shield (Out)
XID
3
Orange / XID Data
12
XID Data
Orange
7
Red/
Water temp. sensor input
13
Water temp.
sensor (+)
Brown
Water temp.
sensor
6
Green/
Water temp. sensor power
14
Water temp.
sensor (power)
White
1
-
15
-
-
2
-
16
-
-
Summary of Contents for CVS-875D
Page 1: ......
Page 2: ......
Page 18: ...Dimensions CVS 875D 877D xvi 0092607072 01 Dimensions CVS 875D Unit mm inch ...
Page 19: ...CVS 875D 877D Dimensions 0092607072 01 xvii CVS 877D Unit mm inch ...
Page 20: ...Dimensions CVS 875D 877D xviii 0092607072 01 Operation unit of CVS 875D 877D Unit mm inch ...
Page 108: ... This page intentionally left blank ...
Page 114: ... This page intentionally left blank ...
Page 122: ......