CVS-875D/877D
Chapter 3 Maintenance
0092607072-01
3-3
Caution: The LED on panel will turn
from green to red if the gain
knob is rotated to right or left, or
one of CM1 ~ CM6 is pressed
and one more pressing will turn
the color to green. In addition,
the internal buzzer will sound
when the gain knob is rotated.
3.4.2 Diagnostics
As self-diagnostics, panel test, LCD test and
XID check can be performed.
As [Panel Test], the present conditions of the
system will be displayed at the upper side of
the display screen in addition to confirmation
of key inputs.
As [LCD Test], display will be switched over
in the order of grid, white, black, red, green
and blue each time the key is pressed.
[XID] can check the received data from the
XID adaptive TD
1. Press .
2. Select [Maintain]
– [System Check].
3. Press [ ] of .
The setup box of [System Check] will be
displayed.
4. When panel test or confirmation of system
status is performed, select [Panel Test]
with [▲] and [▼] keys. For checking of
LCD, select [LCD Test]. For checking of
XID, select [XID].
3.4.2.1 Panel Test
The panel test confirms the key input and
system status.
When [Panel Test] is selected and press [
►]
key, the panel test screen will be displayed.
The system status will be displayed as
shown in the above figure.
For CVS-877D, [CVS-877D Type] will be
displayed at under [Memory].
When a key is pressed, the key will be
identified and the key on the corresponding
screen will change in color. The same key is
pressed subsequently, the System Test
screen will end and the setup box of [System
Check] will be displayed.
(1) [RAM] displays the result of RAM check.
OK if normal, and NG if abnormal, will be
displayed.
(2) [ROM] displays the result of ROM check.
OK if normal, and NG if abnormal, will be
displayed.
(3) [NMEA1] confirms J8 port. As the
confirmation will be performed when the
panel test screen is displayed, mount the
jig before the display of the screen.
“– –” for not yet done, OK for normal case
and NG for abnormal case will be
displayed.
(4) [NMEA2] confirms J3 port. As the
confirmation will be performed when the
panel test screen is displayed, mount the
jig before the display of the screen.
“– –” for not yet done, OK for normal case
and NG for abnormal case will be
displayed.
(5) [Memory] displays the conditions of
internal memory.
Ok for normal case and NG for abnormal
case will be displayed. The used ratio of
memory is also displayed.
Caution: For confirmation of
[NMEA1] and [NMEA2] ports,
the dedicated jig is necessary.
Summary of Contents for CVS-875D
Page 1: ......
Page 2: ......
Page 18: ...Dimensions CVS 875D 877D xvi 0092607072 01 Dimensions CVS 875D Unit mm inch ...
Page 19: ...CVS 875D 877D Dimensions 0092607072 01 xvii CVS 877D Unit mm inch ...
Page 20: ...Dimensions CVS 875D 877D xviii 0092607072 01 Operation unit of CVS 875D 877D Unit mm inch ...
Page 108: ... This page intentionally left blank ...
Page 114: ... This page intentionally left blank ...
Page 122: ......