CVR–010
Basic Operating Instructions
32
7.6. Adjusting TVG Level Manually
(continued – 2/2)
< CAUTION >
With the TVG set at its maximum level during shallow depth operation,
extremely weak bottom echo may result, triggering the bottom–missing
alarm.
Figure 7-23 Parameter Indication for Manual TVG Adjustment – Example
(1) Press
twice to activate the manual control
(
MANUAL
)
mode.
- The TVG level indication will then be
highlighted as in the example at right.
(2) You can now select up to 31 TVG levels
(
TVG = 0
,
minimum to
TVG = 30
, maximum)
by
pressing
/
.
-
Repeatedly
press
to increase the TVG
level until satisfactory results are obtained.
- Too high level at shallow depths may,
however, weaken the bottom echo as well,
leading to unstable depth reading operation.
-
Pressing
decreases the suppression
level.
(3) To return to the
AUTO
mode, press
.
Current TVG level
Manual Control