background image

6

7

Name of each part

Installation

Product Spec

Mic : Voice input

Guard Call Button : 

Used to call guard
Cancel Button : 

Used to cancel calling

KLP-C410

Power Source

Power for internal operation
Lobby Phone Data Type

Call Type

Hands-free Type (2-Way)

PROTOCOL DATA TX/RX Type

Call & Video Waiting Time

30 second waiting time after call, 3 minutes for call to household.

Housing Material

Aluminum (A/L), PC, ABS

Dimension

(W)174 X (H)263 X (D)15 (mm)

Guaranteed Operation

Temperature

-10℃~50℃

LED On Feature

10-Key LED turned on for calling

Video Angle

Feature to adjust up, down, left, right (90°)

None

Link with RF Card

Not linked

13.56MHz

DC 12V

DC 15V~18V
(Standby:4W, Operation:10W)

Product Name

KLP-C410R

DC 15V~18V
(Standby:4W, Operation:10W)

Not linked

KLP-D410

DC 15V~18V
(Standby:3W, Operation:7W)

Components of product

1,50

0

1,22

0

1,78

0

Back case

Main Body

Box

Lobby Phone

Sun visor(Option)

Box(Option)

Mood Lamp : 

Turns on to find it in night time

RF Card Reader : 

Door opens by contacting of RF Card 

(Available only with RF Card Model)

FND Display : 

Displays household

number and during setup

10 Key Dial Button : 

Displays household

number and during setup

Camera Lens : 

Send video image during call

Call Button : 

Used to call household

90°

Wiring Diagram

●For link with sensor :
    - Setup
      J P 1  : No relation
      SW2 :

   - Wiring

      <Fire sensor>
      Pin 7 of CNT7 : Fire sensor (+) 
      Pin 9 of CNT7 : Fire sensor (-)

<PIR sensor>
Pin 8 of CNT7 : PIR sensor (+)

Pin 9 of CNT7 : PIR sensor (-) 

Sensor_GND

●External power connection with Dead bolt
    Pin 5 of CNT7 - Dead bolt_GND
    Pin 6 of CNT7 

 Connect to Dead bolt +

■Lobby Phone Terminals

■Lobby Phone Terminal Connection

●For link with dead bolt : 
   Dead bolt consumes a lot of current, so it is
   essential to connect external power.
   - Setup
      J P 1  : Connect pin 1-2
      SW2 :

- Wiring
   Pin 8 of CNT12 

 Dead bolt +12V

   Pin 9 of CNT12 

 Dead bolt_GND

1

1

3

1

3

2

1

9

JP1

CNT12

CNT7

CNT14

CNT4

SW2

1

10

8

●For link with Automatic Door :
    - Setup
      J P 1  : Connect pin 2-3
      SW2 :

    - Wiring
       Pin 6 of CNT7-Connect Automatic door c and 
       Pin 8 of CNT12-Automatic door contact-(No polarity)

●For link with Striker :
    - Setup
      J P 1  : Connect pin 1-2
      SW2 :

- Wiring
  Pin 8 of CNT12 

 S12V

  Pin 9 of CNT12 

 Connect Striker_GND

●Open/Close Contact
    N/O
    COM
    N/C

A

B

C

D

1

1

3

1

3
1

9

JP1

SW2

1

10

8

CNT14 (Video Output)

8) GND
7) DVR VIDEO Output
6) GND
5) GND
4) Additional Lobby Video Input 2
3) Additional Lobby Video Input 1
2) VIDEO2 Output
1) VIDEO1 Output

A

CNT12 (for household connection)

9) Switch_GND
8) Switch Output (+)
7) DATA
6) VIDEO 1 Output
5) Voice2
4) Voice1
3) GND
2) NC
1) DC+15V

C

CNT7 (Sensor & Switch)

10) Fire & PIR sensor Power (+)
9) Fire & PIR sensor contact & GND
8) PIR sensor contact (+)
7) Fire sensor contact (+) 
6) D/DEAD_BOL
5) DEAD_BOLT/ STRIKER_GND
4) Not Used
3) N/C Contact
2) COM Contact
1) N/O Contact

D

CNT4 Connection

3) GND
2) NC
1) +15V

B

JP1(DOOR TYPE)

2) N/O for 2, 3 connection
1) N/C for 1, 2 connection

Body Sensor

On the basis of
the center of
lobbyphone’s
lens

(Unit : mm)

Standard installation height of lobbyphone is 1,400~1,450mm 
from floor to the bottom of flush mounting box.
In case that the installation height of lobbyphone is out of the 
range (min.1,250mm~1,550mm), it’s hard to get proper 
image, so be careful about the installation height of lobbyphone.

■Standard height for installation of Lobbyphone

Sub videophone 

8P*300mm

Power 

2P*300mm

Household 

9P*300mm

DC 15V~18V / 2.0A  Adapter

Sensor & Switch 

10P*300mm

4×30mm Screw (4ea)

4×10mm Screw (2ea)

4×8mm Bolt (2ea)

3×12mm Screw (1ea)

“L”wench