background image

Using          set the product an it's ID No. you want to make a call and press  
Communication is made available if a user picks up the handset.

LOBBY = Multi-family Lobby Phone

   For making a call to all guard, set the number of GUARD as 99

25

Functional Description

Functional Description

Absent Mode 

24

14. Setting/Cancelling the Absent Mode

If a user presses           button with the handset 
eing hung up, Going-out LED is turned on. 
(To turn the LED off, press the button once again.)

/

/

1. Security sensor inactive during 60 secs. in absent mode(Time for user to go out of the house)
2. In 60 secs. a user can cancel absent mode
3. Absent mode ON after 60 secs. (security sensor active)
4. When alarming, press        button for 2 secs. to cancel the alarm
5. On DEVICE of OSD menu, a user can change absent mode details
6. Alarm call is not made to Private Exchanger

OSD function (LCD CONTROL MENU)

1. CALL (push menu button once)

Call to Multi-family Lobby Phone & Segurity Phone and Private Exchanger

3

CALL

LOBBY1

5

CALL

LOBBY1

2. DEVICE (push menu button twice)

OFF
10MINUTE
NO
2
30SEC
30SEC

DEVICE

SWITCH
ALARM TIME
ALARM CALL
CALL TIMES
CAM1 TIME
CAM2 TIME

1) SWITCH OFF : Devices for each of the connection point are disconnected. 
 

           If a user changes it's condition to 'ON', the devices are connected and take action.

 ※

DOOR OPEN on this means DOOR OPEN is set as CAMERA on Installation Menu and a user cannot

      control SWITCH OFF/ON. 
2) ALARM TIME 10 MINUTES : Alarming for 10 minutes 
    ALARM TIME 30 MINUTES : Alarming for 20 minutes
    ALARM TIME CONTINUE : Continue alarming until cancellation 
 

 

             ( * Alarm cancellation: press          for 2 secs.)

3) ALARM CALL NO : Do not make alarm call
    ALARM CALL GUARD 1 : Make alarm call to GUARD 1
    ALARM CALL GUARD 2 : Make alarm call to GUARD 2
   

CAUTION : Alarm call is not made to Private Exchanger 

/

/

/

Please push menu button for this function. Select and change using 
Contents can be changed according to product's version.

Summary of Contents for KCV-802R

Page 1: ...as shown in the right and specifications are subject to change without notice for quality improvement KC MC30 KC MC31 Option 7inch LCD Call from and two way communication with door camera Going out o...

Page 2: ...tions for safety 8 Key Features 9 Components 10 Monitor Installation 11 Door Camera Installation 12 14 18 Name of Each Part Specifications Wiring Diagram Functional Description 15 30 Warranty Card Con...

Page 3: ...ed on the drawing for example the left drawing instructs user to detach power plug from an outlet Cautions Cautions for installation Be careful not to expose the product to benzene thinner or hot wate...

Page 4: ...ving equipment be sure that plug is detached from an outlet and communication cable is disconnected Damage on cables may cause fire Voltage other than prescribed rated voltage is not permitted which c...

Page 5: ...e and view of the selected image Color control Tone ring change ID setting of house device Input of guard office No in a privately installed exchanger Input of the password No for opening of lobby doo...

Page 6: ...1 550mm it is impossible to control the screen picture with only the lens angle and therefore be careful of the height of camera installation Standard Height of Door Camera Bottom base of One hall Bo...

Page 7: ...ses one or more of 12 keys for extension line after pressing Extension Line button a call signal is sent to a house device or an exchanger phone to which the selected number is assigned In case a trou...

Page 8: ...re than IV 0 65mm only Multi family Main Wiring VOICE1 VOICE2 DATA Polarized more than IV 0 8mm only Video Wiring COAXIAL 5C 2V Power Polarized 2 lines more than IV 1 2mm only Door Camera 50m for 0 65...

Page 9: ...or Opener or Sprinkler or Devices for each of the connection points 1 17V 2 GND 3 VOICE 1 4 VOICE 2 5 VIDEO INPUT 6 DATA 7 PABX internal line 8 DATA PABX 9 VIDEO OUT SUB monitor MAIN monitor Mode Sett...

Page 10: ...a user picks up the handset communication is made available If a user presses button during the communication common gate connected to multi family lobby phone is opened Above descriptions may vary wi...

Page 11: ...tone ring sounds Pick up the handset to communicate with the security phone 5 Call to Multi family Security Phone If a user picks up the handset and presses button Lobby Security LED on and tone ring...

Page 12: ...with pressing the button MENU CALL LOBBY 02 LOBBY GUARD on hanging up the phone CALL GUARD LOBBY 00 02 MENU LCD 12 Selected Call Function of Guard Master After selecting the number on MENU CALL TEL o...

Page 13: ...LCD CONTROL MENU 1 CALL push menu button once Call to Multi family Lobby Phone Segurity Phone and Private Exchanger 3 CALL LOBBY1 5 CALL LOBBY1 2 DEVICE push menu button twice OFF 10MINUTE NO 2 30SEC...

Page 14: ...nstaller Menu LCD OSD Menu 0001 0 0 MULTI OLD CAMERA NORMAL OPEN SYSTEM ID CAMERA1 CAMERA2 MODE PROTOCOL DOOROPEN SENSER INITIAL SYSTME SW Ver X XX 5 Date set up Image deletes function Date time image...

Page 15: ...on will different according to the selected Mode 7 PROTOCOL OLD set for the compatibility with the old common gate systems PROTOCOL NEW It can be set from 1 to 1599 and ID number over 63 8 DOOR OPEN C...

Page 16: ...ollowing cases will be subject to charge even during warranty period a Breakdown during transport or through careless treatment by consumer b Breakdown cause by unauthorized repair or system modificat...