background image

11

10

Installation Precaution

Monitor and camera must be installed away from direct light 
and counter light.
Camera must be installed at a place free from rain.
Standard height of monitor must be 1,450mm~1,500mm from ground, 
centered around brawn tube.
Camera should be installed on the wall in which cement is completely dry.
If installed during winter season at temperature below -5

 

condensation 

might be generated inside monitor and camera due to temperature 
difference between indoors and outdoors. 
To prevent breakdown due to such condensation, connection should be 
made in 2 hours or more after installation.
Do not install monitor and camera in locations subject to direct heating as 
harmful gases may subsequently be emitted in significant amounts. 

Stopping up pipe as above minimizes 
temperature difference between indoors and outdoors, 
and also eliminates moisture and condensation on door 
camera window.

Stop up P.V.C. pipe using

adiabatic substances, to prevent 

air circulation

 Door Camera Installation

Surface-mounting Door Camera Installation 

Standard height of the door camera is 1,400mm~1,450mm from 
the bottom of one camera to the floor.
In case that the height of Door camera exceeds the range of 
min. 1,250mm~1,550mm, it is impossible to control the screen 
picture with only the lens angle, and therefore, be careful of the 
height of camera installation.

Standard Height of Door Camera

Bottom base of
One hall Box 

Surface mount

(unit:mm)

Before installation, do not fail to shut the piping.

 Monitor Installation

Standard height of monitor is ranged 1,450 ~ 1,500 from bottom 
to the center of monitor screen.
For installation, avoid the places where there is any excessive 
humidity,magnetic force, dangerous chemicals, direct ray of sun, 
and any places near a heater which can cause break down.

Standard height monitor

Bottom of 
1 Rectangular
switch box

Center of moniter

(unit:mm)

1

2

3

4

5

Rear

END

Rear

6

4X25mm

Screw

Wall hanger

bracket

3X8mm

Screw

KC-MC30

KC-MC31

Wall

4X25mm

Screw

4X8mm

Screw

Wrench

Name plate

Wall

4X25mm

Screw

4X8mm

Screw

Wrench

Screw

cap

Standard wire strip specification : 6~7mm

Standard wire (AWG) : 16~24(0.5mm~1.2mm)

Camera Terminal Block

Camera

Camera

Rear Bracket

Rear Bracket

Standard wire strip specification : 6~7mm

Standard wire (AWG) : 16~24(0.5mm~1.2mm)

Camera Terminal Block

Do not install the door camera in the place under direct sunlight shines, it may make faint image 
or white stripe or round form line on the image. If this phenomenon appears on the monitor's image, 
it is not mechanical trouble, so please replace the door camera to keep away direct sunlight or 
change the direction of the door camera.

※CAUTION

Summary of Contents for KCV-802R

Page 1: ...as shown in the right and specifications are subject to change without notice for quality improvement KC MC30 KC MC31 Option 7inch LCD Call from and two way communication with door camera Going out o...

Page 2: ...tions for safety 8 Key Features 9 Components 10 Monitor Installation 11 Door Camera Installation 12 14 18 Name of Each Part Specifications Wiring Diagram Functional Description 15 30 Warranty Card Con...

Page 3: ...ed on the drawing for example the left drawing instructs user to detach power plug from an outlet Cautions Cautions for installation Be careful not to expose the product to benzene thinner or hot wate...

Page 4: ...ving equipment be sure that plug is detached from an outlet and communication cable is disconnected Damage on cables may cause fire Voltage other than prescribed rated voltage is not permitted which c...

Page 5: ...e and view of the selected image Color control Tone ring change ID setting of house device Input of guard office No in a privately installed exchanger Input of the password No for opening of lobby doo...

Page 6: ...1 550mm it is impossible to control the screen picture with only the lens angle and therefore be careful of the height of camera installation Standard Height of Door Camera Bottom base of One hall Bo...

Page 7: ...ses one or more of 12 keys for extension line after pressing Extension Line button a call signal is sent to a house device or an exchanger phone to which the selected number is assigned In case a trou...

Page 8: ...re than IV 0 65mm only Multi family Main Wiring VOICE1 VOICE2 DATA Polarized more than IV 0 8mm only Video Wiring COAXIAL 5C 2V Power Polarized 2 lines more than IV 1 2mm only Door Camera 50m for 0 65...

Page 9: ...or Opener or Sprinkler or Devices for each of the connection points 1 17V 2 GND 3 VOICE 1 4 VOICE 2 5 VIDEO INPUT 6 DATA 7 PABX internal line 8 DATA PABX 9 VIDEO OUT SUB monitor MAIN monitor Mode Sett...

Page 10: ...a user picks up the handset communication is made available If a user presses button during the communication common gate connected to multi family lobby phone is opened Above descriptions may vary wi...

Page 11: ...tone ring sounds Pick up the handset to communicate with the security phone 5 Call to Multi family Security Phone If a user picks up the handset and presses button Lobby Security LED on and tone ring...

Page 12: ...with pressing the button MENU CALL LOBBY 02 LOBBY GUARD on hanging up the phone CALL GUARD LOBBY 00 02 MENU LCD 12 Selected Call Function of Guard Master After selecting the number on MENU CALL TEL o...

Page 13: ...LCD CONTROL MENU 1 CALL push menu button once Call to Multi family Lobby Phone Segurity Phone and Private Exchanger 3 CALL LOBBY1 5 CALL LOBBY1 2 DEVICE push menu button twice OFF 10MINUTE NO 2 30SEC...

Page 14: ...nstaller Menu LCD OSD Menu 0001 0 0 MULTI OLD CAMERA NORMAL OPEN SYSTEM ID CAMERA1 CAMERA2 MODE PROTOCOL DOOROPEN SENSER INITIAL SYSTME SW Ver X XX 5 Date set up Image deletes function Date time image...

Page 15: ...on will different according to the selected Mode 7 PROTOCOL OLD set for the compatibility with the old common gate systems PROTOCOL NEW It can be set from 1 to 1599 and ID number over 63 8 DOOR OPEN C...

Page 16: ...ollowing cases will be subject to charge even during warranty period a Breakdown during transport or through careless treatment by consumer b Breakdown cause by unauthorized repair or system modificat...

Reviews: