4
Installation location
After fix the rear bracket with 4 screw, put the Door Camera into the grooves of rear bracket,
and then fix it with hexagon screws and stick the finishing materials.
■ Monitor installation
■Door camera installation
KC -MC30
KC-MC24
KC-MC20
KC-C60
■ Directly connecting cut-off power cord with power wire
1) Do not do such electric work on your own. Installing product in this way
requires reliance on electric installation man with electric work license.
2) Insulate with insulating tape while cutting off power cord and connecting with power
wire so electric wire metal does not expose. Contact between exposed electric wires
cause fire or electric shock accident.
3) Such electric work requires connection after interception of supplied power.
1) Remove wall-hanger bracket metal behind monitor.
2) Install wall-hanger bracket metal on 1 type box or wall with attached Vis.
3) Connect wiring to monitor back terminal referring to product connection diagram.
4) Hang monitor on wall-hanging metal, and fix monitor on wall- hanger bracket metal using attached Vis.
5) Plug monitor’s power plug into consent and check to see if the power switch is [ON]
on the left side of monitor.
Wall
Screw
(2X8mm)
Main body
supporter
Screw
(3X5mm)
Wall
Screw
(4X16mm)
Camera
front
Screw
(4X10mm)
Wall
baby support
Upward support
Screw
(2.6X6mm)
Camera
front
Screw
(4X10mm)
■ Monitor installation location
·Standard monitor installation height
is about 1,500mm where screen
center is at eye level.
In this case, wall-hanging metal
center (center of piping) is 1,450mm
above ground level.
·Standard installation height
■ Caution of camera installation
·Avoid installing camera exposed to direct ray of light (and sun).
·Beware backlight and darkness of visitor’s face, which makes identification difficult.
·Avoid installing camera in places such as the following picture.
(1) Place illuminating sky as background
(2) Place with white wall reflecting direct ray of light
(3) Place with direct ray of light
·Standard installation in height
■ Camera installation location
·Camera installation in height Standard
camera installation height is when
lens is about 1,400mm above the floor.
In this case, camera stack center
(piping box) is above 1,390mm above
ground level.
·Standard installation in height
Wall
4X25mm
Screw
4X8mm
Screw
Rear Bracket
Camera Terminal Block
Camera front
Wrench
Name plate
Standard wire strip specification : 6~7mm
Standard wire (AWG) : 16~24(0.5mm~1.2mm)
※
Summary of Contents for KCV-434SD