10. Order Codes
(Example: VKP-1020 R25 S)
Standard version
For viscous media
For soiled media
(particle size max. 400
m)
Connection Contacts
(not for
VKP-3..)
l/min H
2
O
Order no.
l/min. Oil
Order no.
l/min H
2
O Order
no.
2-20
VKP-1020...
1-18
VKP-2018...
7.5-32.5
VKP-3032...
..R25..
= G 1 AG (standard)
..N25..
= 1 NPT AG
..L18..
= Sold. connection 18 mm
..L22..
= Sold. connection 22 mm
..PVC..
=PVC - glue - in c. 20 mm
..IG1..
= G 1/2 IG, brass
..IG2..
= G 1/2 IG, st. steel
..AG1..
= G 1/2 AG, brass
..AG2..
= G 1/2 AG, st- steel
..AG3..
= G 3/4 AG, brass
..AG4..
= G 3/4 AG, st. steel
0
= without
S
= N/O
C
= N/C
5-35
VKP-1035...
2-30
VKP-2030...
10-45
VKP-3045...
5-50
VKP-1050...
5-45
VKP-2045...
15-70
VKP-3070...
10-80
VKP-1080...
10-75
VKP-2075...
20-200
VKP-3100...
20-100
VKP-1100...
-
-
-
-
11. Maintenance
In case the medium to be measured is free from contamination, VKP devices are
almost maintenance-free. If lime or dirt deposits on the housing or inside the inte-
rior of device, then device needs to be cleaned on regular basis. By means of a
proper fork-wrench, the device may be withdrawn from the piping. Clean the flow
meter with a suitable cleaning-agent or use ultrasonic bath.