VKP
page 4
VKP K02/0416
Materials
Material
Remarks
Housing Polysulfone
Float Polysulfone
Spring
St. Steel 1.4310
Metering ring
St.Steel 1.4310
Flat-seal
NBR
brass conne
PVC
Flat-seal
FPM
st. st. connections
Flat-seal
Klingerit-Oilit
oil measuring range
4. Operating
Principle
In the cylindrical housing is located a float with an orifice. This float element is
raised by the medium flowing in, against the strength of a spring. Each float ele-
ment position corresponds to a flow value, which can be read off from the scale
mounted on the housing. Optionally, a float element with permanent magnet can
be mounted which activate a reed-contact mounted outside the body of the unit.
The operation of the contact succeeds contactlessly via magnetic force, i.e. the
contact is hermetically separated from the flowing medium. The type VKP is
equipped with a float element, which is provided with grooves on the exterior in
order to protect it against contamination caused by deposited particles. Thus the
danger of clamping the float element is substantially reduced and measuring
polluted liquids with a particle size of up to 400 µm is possible without problems.
5. Instrument
Inspection
Instruments are inspected before shipping and sent out in perfect condition.
Should damage to a device be visible, we recommend a thorough inspection of
the delivery packaging. In case of damage, please inform your parcel service /
forwarding agent immediately, since they are responsible for damages during
transit.
Scope of delivery:
The standard delivery includes:
Plastic Flow Meter and Monitor model: VKP
Operating Instructions