Kobold URK series Operating Instructions Manual Download Page 7

URK 

URK K03/0817 

page 7

 

12. Dimensions 

 
 
 
 
 
 
 
 
 
 
 
 
 

Model H 

[mm] 

DIN

ANSI 

DN 

PN 6

PN 16

Size 

Class 150 RF

D

1

 [mm] 

D

2

[mm]

D

1

[mm]

D

2

[mm]

D

1

 [mm] 

D

2

[mm]

URK-..4x 380 

15

80 55

95

65

½" 88.9 

60.5

URK-..5x 

390 

20

90 65

105

75

¾" 98.6 

69.9

URK-..6x 

390 

25

100 75

115

85

1" 108.0 

79.2

URK-..7x 

400 

32

120 90

140

100

1¼" 

117.3 

88.9

URK-..8x 410 

40

130 100

150

110

1½" 127.0 

98.6

URK-..9x 

410 

50

140 110

165

125

2" 152.0 

120.7

URK-..Ax 

550 

65

160 130

185

145

2½" 177.8 

139.7

URK-..Bx 

560 

80

190 150

200

160

3" 190.5 

152.4

Material combination URK 

Ordering 

code Connection  Float 

Seal 

Ring 

Housing 

Sight 

glass 

Measuring 

cone 

73 cast 

iron 

1.4301  NBR  PVC 

st.st. 

1.4301 

plexiglass 

borosilicate 

glass 

33 1.4301 

1.4301 FPM  PTFE 

55 1.4404 

1.4404 FPM  PTFE 

99

**

 cast 

iron 

1.4301 
1.4404 

1.4301 
1.4404 

aluminium 

PTFE 

PVC 

PP 

NBR 

EPDM 

FPM 

PTFE 

PVC 

PTFE 

1.4301 

** Customer specification on request 

Summary of Contents for URK series

Page 1: ...Operating instructions for Variable area flow meter Model URK...

Page 2: ...4 9 Maintenance 5 10 Technical information 5 11 Order codes 6 12 Dimensions 7 13 EU Declaration of conformance 8 Manufactured by Sold by Kobold Unirota Ltd Kobold Messring GmbH 4400 Ny regyh za Nordri...

Page 3: ...E mark pipeline filled with gas liquids group 2 group 1 group 2 table 7 table 8 table 9 3 Instrument inspection Instruments are inspected before shipping and sent out in perfect condition Should damag...

Page 4: ...glass which optically allows direct flow observation 6 Mechanical connection Before Installation Remove all transportation safety locks and ensure that no packing material remains within the unit Be...

Page 5: ...ly maintenance free If deposits form on the inner housing or parts periodic cleaning of the unit is recommended Remove the units from the piping with a suitable tool clean the flow meter with a suitab...

Page 6: ...15H 16 160 15L 0 5 5 28 F6 DN 25 B5 DN 20 B6 DN 25 A6 1 A7 1 17H 25 250 17L 0 8 8 28 19H 40 400 19L 1 3 13 36 21H 63 630 21L 2 0 20 34 23H 100 1 000 23L 3 2 32 43 25H 160 1 600 25L 5 50 48 F7 DN 32 B...

Page 7: ...110 1 127 0 98 6 URK 9x 410 50 140 110 165 125 2 152 0 120 7 URK Ax 550 65 160 130 185 145 2 177 8 139 7 URK Bx 560 80 190 150 200 160 3 190 5 152 4 Material combination URK Ordering code Connection...

Page 8: ...ial EN 55011 2009 A1 2010 ISM ratio frequency equipment EN 61326 1 2013 Electrical equipment for measurement control and laboratory use EMC requirements EN 61010 1 2011 Safety requirements for electri...

Reviews: