Kobold URK series Operating Instructions Manual Download Page 6

URK 

page 6 

URK K03/0817

 

11. Order codes 

Model 

Material 

combi- 

nation 

Measuring range 

Pressure 

loss 

[mbar] 

Flange 

Contacts 

water [L/h] 

air [m³

N

/h] 

DIN 2526. 

Form C. PN 6 

DIN 2526. 

Form C. PN 16 

ANSI 

150 lbs 

URK- 

73 

33 

55 

99** 

 

01L = 0.02…0.2

10

F4 = DN 15 

F5 = DN 20 

B4 = DN 15 

A4 =½" 

A5 = ¾" 

0  = no  
contact 

P* = 1 PNP 
normally open 

R* = 2 PNP 
normally open 

03H = 1…10 

03L = 0.032…0.32

10

05H = 1.6…16 

05L = 0.05…0.5

10

07H = 2.5…25 

07L = 0.08…0.8

12

09H = 4.0…40 

09L = 0.13…1.3

9

11H = 6.3…63 

11L = 0.2…2.0

17

13H = 10…100 

13L = 0.32…3.2

24

15H = 16…160 

15L = 0.5…5

28

F6 = DN 25 

B5 = DN 20 

B6 = DN 25 

A6 = 1" 

A7 = 1 ¼" 

17H = 25…250 

17L = 0.8…8

28

19H = 40…400 

19L = 1.3…13

36

21H = 63…630 

21L = 2.0…20

34

23H = 100…1 000

23L = 3.2…32

43

25H = 160…1 600

25L = 5…50

48

F7 = DN 32 

B7 = DN 32 

A8 = 1 ½" 

27H = 250…2 500

27L = 8…80

48

29H = 400…4 000

29L = 13…130

51

F8 = DN 40 

B8 = DN 40 

A9 = 2" 

31H = 630…6 300

31L = 20…200

57

33H = 1 000…10 000 

33L

***

= 25…250

70

F9 = DN 50

B9 = DN 50 

35H = 1 600…16 000 

35L

***

= 32…320

93

FA = DN 65 

BA = DN 65 

AA = 2 ½" 

AB = 3" 

37H = 2 500…25 000 

37L

***

= 40…400

102

39H = 10 000…40 000 

39L

***

= 50…500

95

FB = DN 80 

BB = DN 80 

– 

41H = 15 000…50 000 

  

102

*Other switching functions on request  
**Customer specification on request 
*** 33L; 35L; 37L and 39L air ranges only available with aluminum or PTFE float 

Summary of Contents for URK series

Page 1: ...Operating instructions for Variable area flow meter Model URK...

Page 2: ...4 9 Maintenance 5 10 Technical information 5 11 Order codes 6 12 Dimensions 7 13 EU Declaration of conformance 8 Manufactured by Sold by Kobold Unirota Ltd Kobold Messring GmbH 4400 Ny regyh za Nordri...

Page 3: ...E mark pipeline filled with gas liquids group 2 group 1 group 2 table 7 table 8 table 9 3 Instrument inspection Instruments are inspected before shipping and sent out in perfect condition Should damag...

Page 4: ...glass which optically allows direct flow observation 6 Mechanical connection Before Installation Remove all transportation safety locks and ensure that no packing material remains within the unit Be...

Page 5: ...ly maintenance free If deposits form on the inner housing or parts periodic cleaning of the unit is recommended Remove the units from the piping with a suitable tool clean the flow meter with a suitab...

Page 6: ...15H 16 160 15L 0 5 5 28 F6 DN 25 B5 DN 20 B6 DN 25 A6 1 A7 1 17H 25 250 17L 0 8 8 28 19H 40 400 19L 1 3 13 36 21H 63 630 21L 2 0 20 34 23H 100 1 000 23L 3 2 32 43 25H 160 1 600 25L 5 50 48 F7 DN 32 B...

Page 7: ...110 1 127 0 98 6 URK 9x 410 50 140 110 165 125 2 152 0 120 7 URK Ax 550 65 160 130 185 145 2 177 8 139 7 URK Bx 560 80 190 150 200 160 3 190 5 152 4 Material combination URK Ordering code Connection...

Page 8: ...ial EN 55011 2009 A1 2010 ISM ratio frequency equipment EN 61326 1 2013 Electrical equipment for measurement control and laboratory use EMC requirements EN 61010 1 2011 Safety requirements for electri...

Reviews: