Kobold URK series Operating Instructions Manual Download Page 4

URK 

page 4 

URK K03/0817

 

5. Operating principle 

 

The Kobold URK model flowmeter/monitor works on the basis of the suspended float principle. It 
is used for measuring the flow rates in closed pipe line systems. 
The medium flows from below through a glass measuring cone that gets wider on top. Thus, the 
float is raised and indicates the respective flow rate on the scale provided on the measuring 
cone. To monitor flow rate limits, the URK meters can be optionally furnished with “open 
collector“ proximity switches. 

By its special design, this model is particularly suitable for applications where only very 
small operating pressures are available. Another advantage is offered by the very large 
sight glass which optically allows direct flow observation. 
 
 
 

6. Mechanical connection

 

Before Installation: 
•  Remove all transportation safety locks and ensure that no packing material remains within 

the unit. 

•  Be sure that the maximum allowable operating pressure and temperature is not exceeded 

(see Technical data). 

•  Install the by-pass level indicator at the side of the round containers, ensure the instrument 

is under no mechanical stress/tension (install support bracing if necessary). 

•  Protect the measuring tube from external damage. 
•  Avoid pressure peaks in the measuring tube, e.g. from sudden surges or stoppage of flow. 
•  If possible, immediately after making mechanical connections, check whether the 

connections are properly sealed with no evidence of leakage. 

•  Make sure that the connections are in plain.  

 

7. Electrical connection 

7.1. Inductive switch (option) 

• Make sure that the supply wires are de-energized. 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for URK series

Page 1: ...Operating instructions for Variable area flow meter Model URK...

Page 2: ...4 9 Maintenance 5 10 Technical information 5 11 Order codes 6 12 Dimensions 7 13 EU Declaration of conformance 8 Manufactured by Sold by Kobold Unirota Ltd Kobold Messring GmbH 4400 Ny regyh za Nordri...

Page 3: ...E mark pipeline filled with gas liquids group 2 group 1 group 2 table 7 table 8 table 9 3 Instrument inspection Instruments are inspected before shipping and sent out in perfect condition Should damag...

Page 4: ...glass which optically allows direct flow observation 6 Mechanical connection Before Installation Remove all transportation safety locks and ensure that no packing material remains within the unit Be...

Page 5: ...ly maintenance free If deposits form on the inner housing or parts periodic cleaning of the unit is recommended Remove the units from the piping with a suitable tool clean the flow meter with a suitab...

Page 6: ...15H 16 160 15L 0 5 5 28 F6 DN 25 B5 DN 20 B6 DN 25 A6 1 A7 1 17H 25 250 17L 0 8 8 28 19H 40 400 19L 1 3 13 36 21H 63 630 21L 2 0 20 34 23H 100 1 000 23L 3 2 32 43 25H 160 1 600 25L 5 50 48 F7 DN 32 B...

Page 7: ...110 1 127 0 98 6 URK 9x 410 50 140 110 165 125 2 152 0 120 7 URK Ax 550 65 160 130 185 145 2 177 8 139 7 URK Bx 560 80 190 150 200 160 3 190 5 152 4 Material combination URK Ordering code Connection...

Page 8: ...ial EN 55011 2009 A1 2010 ISM ratio frequency equipment EN 61326 1 2013 Electrical equipment for measurement control and laboratory use EMC requirements EN 61010 1 2011 Safety requirements for electri...