24
10. TECHNICAL DATA KMT-4
Measuring value
Flow
Measurand
Volumetric flow at standard conditions acc. DIN 1343
P
0
= 1013.25 mbar
(14.7 PSI)
; t
0
= 0 °C
(32 °F)
Measuring range
0.2...100 Nm/s
(40...19685 SFPM)
or 0.2...200 Nm/s
(40...39370 SFPM)
Accuracy
in air at 9 bar (130.5 psi) (abs) and 23 °C (73 °F)
1)
± (1.5 % of measuring value + 0.8 % of full scale)
Temperature coefficient
± (0.1 % of measuring value / °C)
Pressure coefficient
2)
+ 0.5 % of measuring value / bar
Response time t
90
< 1 sec.
Sample rate
0.5 sec.
Temperature
Measuring range
-20...80 °C
(-4...176 °F)
Accuracy
at 20 °C (68 °F)
± 0.7 °C
(1.26 °F)
Outputs
Output signal and display ranges are freely scalable
Analogue output
voltage
0 - 10 V
max. 1 mA
current (3-wire) 0 - 20 mA and 4 - 20 mA R
L
<500 Ohm
Switching output
potential-free max. 44 VDC, 500 mA switching capacity
Pulse output
Totalizer, pulse length: 0.02...2 sec.
Digital interface
USB (for configuration)
Input
Optional pressure compensation
4 - 20 mA (2-wire; 15 V) for pressure sensor
General
Supply voltage
18 - 30 V AC/DC
Current consumption
max. 200 mA
Temperature range
ambient temperature:
-20...60 °C
(-4...140 °F)
medium temperature:
-20...80 °C
(-4...176 °F)
storage temperature:
-20...60 °C
(-4...140 °F)
Humidity working range
0...99 %RH no condensation
max. working pressure
16 bar
(232 psi)
Medium
compressed air or Non-Corrosive gases
Electrical connection
cable gland M16x1.5
Electromagnetic compatibility
EN61326-1
EN61326-2-3
Industrial Environment
Material
housing
metal (AlSi3Cu)
probe
stainless steel
sensor head
stainless steel / galss
non-return protection brass
Housing protection class
IP65 / Nema 4
1) The accuracy statement includes the uncertainty of the factory calibration with an enhancement factor k=2 (2-times standard deviation). The accuracy was
culated in accordance with EA-4/02 and with regard to GUM (Guide to the Expression of Uncertainty in Measurement).
2) The flow meter is calibrated at 9 bar (abs) 130.5 psi. If the working pressure is different from 9 bar (130.5 psi) you can compensate the error by setting the actual pres-
sure with the configuration software.
Flow measuring range in dependence on pipe diameter
pipe
inner Ø
measuring range
mm
(inch)
0.2...100 Nm/s
(40...19685 SFPM)
0.2...200 Nm/s
(40...39370 SFPM)
DN50 / 2“
54.5
(2.15“)
1.7...839 Nm
3
/h
1.0...493.8 SCFM
1.7...1679 Nm
3
/h
1.0...987.6 SCFM
DN65 / 2 1/2“ 70.3
(2.77“)
2.8...1397 Nm
3
/h
1.6...821.6 SCFM
2.8...2793 Nm
3
/h
1.6...1643.2 SCFM
DN80 / 3“
82.5
(3.25“)
3.8...1923 Nm
3
/h
2.3...1131.5 SCFM
3.8...3847 Nm
3
/h
2.3...2263.0 SCFM
DN100 / 4“
107.1
(4.22“)
6.5...3242 Nm
3
/h
3.8...1906.9 SCFM
6.5...6483 Nm
3
/h
3.8...3813.8 SCFM
DN125 / 5“
131.7
(5.19“)
9.8...4902 Nm
3
/h
5.8...2883.5 SCFM
9.8...9803 Nm
3
/h
5.8...5766.9 SCFM
DN150 / 6“
159.3
(6.27“)
14.3...7171 Nm
3
/h
8.4...4218.7 SCFM
14.3...14343 Nm
3
/h
8.4...8437.3 SCFM
DN200 / 8“
206.5
(8.13“)
24.1...12051 Nm
3
/h
14.2...7089.0 SCFM
24.1...24101 Nm
3
/h
14.2...14178.0 SCFM
DN250 / 10“ 260.4
(10.25“)
38.3...19163 Nm
3
/h
22.5...11272.6 SCFM
38.3...38325 Nm
3
/h
22.5...22545.3 SCFM
DN300 / 12“ 309.7
(12.19“)
54.2...27105 Nm
3
/h
31.9...15945.1 SCFM
54.2...54211 Nm
3
/h
31.9...31890.1 SCFM
DN350 / 14“ 339.6
(13.37“)
65.2...32591 Nm
3
/h
38.3...19172.5 SCFM
65.2...65183 Nm
3
/h
38.3...38345.0 SCFM
DN400 / 16“ 388.8
(15.31“)
85,4...42719 Nm
3
/h
50.3...25130.2 SCFM
85.4...85438 Nm
3
/h
50.3...50260.0 SCFM
DN500 / 20“ 486
(19.13“)
133,5...66749 Nm
3
/h
78,5...39266.0 SCFM
133.5...133498 Nm
3
/h
78,5...78531.9 SCFM
DN600 / 24“ 585
(23.03“)
193,4...96712 Nm
3
/h
113.8...56892.6 SCFM
193.4...193425 Nm
3
/h
113.8...113785.1 SCFM
DN700 / 28“ 682.6
(26.87“)
263,4...131675 Nm
3
/h
154.9...77459.8 SCFM
263.4...263350 Nm
3
/h
154.9...154919.6 SCFM
Summary of Contents for KMT-1