![Kobold Heinrichs TM Supplementary Operating Manual Download Page 10](http://html1.mh-extra.com/html/kobold/heinrichs-tm/heinrichs-tm_supplementary-operating-manual_1982332010.webp)
Heinrichs Messtechnik GmbH
Page 10 of 20
TM/TMU/TM-SH Supplement Manual
For Explosion Flow-meters
3.5
Electrical Parameters
Warning
To ensure compliance with the requirements for explosive atmospheres, it is essential
that the maximum electrical and thermal values set forth below are observed
3.5.1
Exciter circuit (terminals 8 and 9)
3.5.1.1
For exciter circuit type EC1
Voltage
Ui
30 V
Current
Ii
90 mA
Power
Pi
0.4 W
Effective internal capacitance
Ci negligible
Effective internal inductance
Li
4.38 mH
3.5.1.2
For exciter circuit type EC2
For connecting an intrinsically safe circuit with an Ex ia IIC type of protection, linear output
characteristic and the following maximum values:
Voltage
Uo
30 V
Current
Io
90 mA
Power
Po
1 W
Effective internal inductance
Li
4.38 mH < Li < 220 mH
3.5.2
Sensor circuits (terminals 1 – 2 and 3 – 4)
Voltage
Ui DC 30 V
Current
Ii
50 mA
Power
Pi
0.300 W
Effective internal capacitance
Ci negligible
Effective internal inductance
Li
14 mH
Output voltage
Uo
AC 0.3 V
3.5.3
Temperature sensor circuits (terminals 5 to 7)
Voltage
Ui DC
30 V
Current
Ii
100 mA
Power
Pi
0.333 W
Effective internal capacitance
Ci negligible
Effective internal inductance
Li negligible