9.1.4
Removal of oval gears for DON-x25…DON-x40 (refer exploded
view)
For access to the oval gears, remove the 8 upper meter body screws (5). With
care, remove the upper meter body assembly (4) being careful not to damage or
misplace the O-ring (3). You can then remove the oval gears (2).
2
2
3
4
5
6
7
8
9
10
11
12
13
1