The individually specified maximum electrical values of the reed switch must
never be exceeded, even for a moment. Higher switching values may reduce the
service life or even destroy the contact.
For capacitive and inductive loads (e.g. via long lines), we recommend the
following protective circuits:
Lamp load with series or parallel
Protection with a RC suppressor
resistance to the reed switch.
For a.c. current and inductive load.
Protection with a diode
Protection with an inductance or
for d.c. current and inductive load.
Resistance for capacitive load.