2.  Note 

Please read these operating instructions before unpacking and putting the unit into 
operation. Follow the instructions precisely as described herein.  
The instruction manuals on our website www.kobold.com are always for currently 
manufactured version of our products. Due to technical changes, the instruction 
manuals available online may not always correspond to the product version you 
have  purchased.  If  you  need  an  instruction  manual  that  corresponds  to  the 
purchased  product  version,  you  can  request  it  from  us  free  of  charge  by  email 
([email protected]) in PDF format, specifying the relevant invoice number and 
serial number. If you wish, the operating instructions can also be sent to you by 
post in paper form against an applicable postage fee.

 

 
The devices are only to be used, maintained and serviced by persons familiar with 
these operating instructions and in accordance with local regulations applying to 
Health & Safety and prevention of accidents.  
 
When  used  in  machines,  the  measuring  unit  should  be  used  only  when  the 
machines fulfil the EC-machine guidelines. 
 
 

3.  Instrument Inspection 

Instruments are inspected before shipping and sent out in perfect condition.  
Should damage to a device be visible, we recommend a thorough inspection of the 
delivery  packaging.  In  case  of  damage,  please  inform  your  parcel  service  / 
forwarding  agent  immediately,  since  they  are  responsible  for  damages  during 
transit. 
 

Scope of delivery: 

The standard delivery includes: 

  Digital Indicating Unit  

model: DAG-A1V 

 
 
 

4.  Regulation Use 

Any  use  of  the  device,  which  exceeds  the  manufacturer’s  specification,  may 
invalidate its warranty. Therefore, any resulting damage is not the responsibility of 
the manufacturer. The user assumes all risk for such usage.  
 
 
 

Summary of Contents for DAG-A1V

Page 1: ...Operating Instructions for Digital Indicating Unit for Panel Mounting Model DAG A1V Standard Signal 0 4 20 mA 0 10 VDC...

Page 2: ...ontents 2 2 Note 3 3 Instrument Inspection 3 4 Regulation Use 3 5 Brief description 4 6 Assembly 4 7 Electrical Connection 5 8 Function description and operation 6 9 Setting up the device 7 9 1 Switch...

Page 3: ...e fee The devices are only to be used maintained and serviced by persons familiar with these operating instructions and in accordance with local regulations applying to Health Safety and prevention of...

Page 4: ...s Selectable functions like e g the recall of the min max value a zero point slowdown a direct change of the limit value in operating mode and additional measuring supporting points for linearisation...

Page 5: ...AG A1V K06 0722 page 5 7 Electrical Connection Type DAG A1V3000R supply of 24 VDC galvanically isolated Connection examples Below you find some connection examples which demonstrate some practical app...

Page 6: ...always indicated with a flashing of the display Adjustments made at the parameterization level should be always confirmed by pressing the P key to save them However the display automatically saves all...

Page 7: ...ce For 1 second during the switching on process the segment test 8 8 8 8 8 is displayed followed by an indication of the software type and after that also for 1 second the software version After the s...

Page 8: ...ogramming interlock RUN 9 4 Extended parameterization By pressing the buttons during standard parameterization for one second the display switches to the extended parameterization mode Operation is th...

Page 9: ...DAG A1V DAG A1V K06 0722 page 9...

Page 10: ...DAG A1V page 10 DAG A1V K06 0722...

Page 11: ...following procedure should be used Switch off the power supply Press button P Switch on voltage supply and press P button until is shown in the display With reset the default values of the program ta...

Page 12: ...1 S2 is on below the threshold and switched off on reaching the threshold Alarms optical setpoint display An activated setpoint can be optically indicated by flashing of the 7 segment display Function...

Page 13: ...5 mm2 Display Digit height 10 mm Segment colour red optional green orange or blue Display range 1999 to 9999 Setpoints optical display flashing Overflow horizontal bars at the top Underflow horizontal...

Page 14: ...emperature 0 C 60 C Storing temperature 20 C 80 C Weatheringresistance relative humidity 0 80 on years average without dew EMV EN 61326 CE sign Conformity to directive 2014 30 EU Safety standard Accor...

Page 15: ...ent Direct voltage Housing size 48x24 mm DAG A1V3000R DAG A1V 3 0 0 0 R Supply 3 24 VDC galvanic separated Output 0 without Sensorsupply 0 without Contacts 0 without Display colour R red B blue O oran...

Page 16: ...ic fields in the vicinity of the device e g due to transformers mobile phones or electrostatic discharge The fuse rating of the supply voltage should not exceed a value of 0 5 A N B fuse Do not instal...

Page 17: ...tion High voltages can cause dangerous body currents Galvanic isolated potentials within one complex need to be placed on an appropriate point normally earth or machines ground So a lower disturbance...

Page 18: ...input with a low voltage signal it is only connected on one side or the input is open Not all of the activated supporting points are parameterised Check if the relevant parameters are adjusted correc...

Page 19: ...ional disposal regulations and environmental regulations Batteries Batteries containing pollutants are marked with a sign consisting of a crossed out garbage can and the chemical symbol Cd Hg Li or Pb...

Page 20: ...or measurement control and laboratory use Part 1 General requirements EN 61326 1 2013 Electrical equipment for measurement control and laboratory use EMC requirements Part 1 General requirements EN IE...

Reviews: