DAG-A1T
DAG-A1T
K05/0722page 13
12. Technical Information
Housing
Dimensions
48x24x27 mm (BxHxD)
48x24x54 mm (BxHxD) including plug-in terminal
Panel cut-out
45.0
+0.6
x 22.20
+0.3
mm
Insulation thickness
up to 3 mm
Fixing
snap-in screw element
Material
PC Polycarbonate, black, UL94V-0
Sealing material
EPDM, 65 Shore, black
Protection class
standard IP65 (front), IP00 (back side)
Weight
approx. 100 g
Connection
plug-in terminal; wire cross section up to 2.5 mm
2
Display
Digit height
10 mm
Segment colour
red (optional green, orange or blue)
Display range
-1999 to 9999
Setpoints
optical display flashing
Overflow
horizontal bars at the top
Underflow
horizontal bars at the bottom
Display time
0.1 to 10.0 seconds
Input
Measuring range
Measuring fault
(at 1 sec measuring time)
Digit
Typ L (Fe-CuNi alter Typ)
-200…900 °C
2K
±1
Typ J (Fe-CuNi)
-210…1200 °C
2K
±1
Typ K (NiCr-NiAL)
-270…1372 °C
2K
±1
Typ B (Pt30Rh-Pt6Rh)
80…1820 °C
2K
±1
Typ S (Pt10Rh-Pt)
-50…1768 °C
2K
±1
Typ N (NiCrSi-NiSi)
-270…1300 °C
2K
±1
Typ E (NiCr-CuNi)
-270…1000 °C
2K
±1
Typ T (Cu-Cu-Ni)
-270…400 °C
2K
±1
Typ R (Pt13Rh-Pt)
-50…1768 °C
2K
±1
Characteristic line failure
< ±1K
Reference junction
Semiconductor sensor