7.2 Dimensions and mounting positions
7.2.1 Installation site
When choosing the installation site, please take into consideration the following safety
instructions:
Caution!
Do not install the BOILER in spaces that are exposed to freezing! In case of
freezing the sation can be damaged.
This equipment can not be installed and used in open air. Outdoor installation can cause
functioning flaws.
Caution!
It is not recommended to install the central heating BOILER in bathrooms or kitchens or
other areas with high humidity.
The BOILER can be installed only in rooms with maximum 60% humidity between 20-30°C
in order to prevent the damaging of electronic components.
Caution!
The burning air of the BOILER must not contain substances such as flourine
vapours, chlorine, sulphur, dissolvants, colorants, adhesives or gasoline. These
substances can lead in time to the corrosion of the equipment and air/ gas
incoming/ outgoing pipes.
Fig. 1.2 Dimensions and mounting positions
Legend:
A – Thermal input
connector
B – Hot water output
connector
C - Fuel input connector
D - Cold water input
connector
E - Thermal output
connector
EN
USER MANUAL C33GC24