background image

 

In  the  single  reset  menu,  the  desired  scale  is  selected  with  the  up  arrow  or  down  arrow  and  the 

weighing weight data of the selected  scale  is displayed on the screen.In this menu if you pres the 

 key, resetting is done in the selected scale. Press * ESC + key to exit the menu and return to the 

main display.  

4.4 PEAK SCREENING 

Press the  

  key to enter the Peak menu.  

 

The  Peak  weight  menu  keeps  the  peak  value  of  the  current  weighing  weight  data.  Scales  can  be 

selected with up arrow  or down arrow.  *Clear +  key brings the  value  on the  screen to the  current 
weight value.  Press  *  ESC +  key to exit the  menu and return to  the  main display. After exiting this 
menu, the captured peak value will not be lost. 

4.5 TARE SCREENING 

Press the  

 key to enter the tare menu.  

 

The  taring  menu  is  used  to  display  the  net  weight.  Scales  can  be  selected  with  up  arrow  or  down 

arrow. If the 

 key is pressed, the weight value of the selected scale is taken as tare and the screen 

is reset. If * Clear + is pressed in this menu, Tare is canceled. After taring, the Tare icon is shown in 
the  main  display.  If  you  want  to  cancel  the  tare  while  in  main  display,  press  *  Clear  +  key  after 
entering this menu and selecting the desired scale. Press * ESC + key to exit the menu and return to 
the main display. 

Summary of Contents for WEI

Page 1: ...WEI WIRELESS INDICATOR USER MANUAL...

Page 2: ...CONTENTS 1 General Description 2 Technical Specifications 3 Description of Function Keys 4 Use of the Device 5 Menular Login 6 Menu Tree...

Page 3: ...play 8 load cells 350 Ohm can be connected to the wireless transmitter module it works with Tensile and breakout tests can be performed with the Peak hold feature When more than one balance is connect...

Page 4: ...he printer It is used to enter the menus and to switch the menus Enters the Peak menu Keeps the current peak value of the weighing The desired scale can be selected with the up arrow or down arrow Del...

Page 5: ...eight data has become steady state 3 Displaying the Tare icon shows the net weight of the weigh weight data 4 The display of the M symbol indicates that the weighing weight data has been saved 5 This...

Page 6: ...the key to enter the reset menu Group reset or single reset is selected to reset the weighing If group reset is selected all of the scales are reset If single reset is selected the desired scale can...

Page 7: ...e screen to the current weight value Press ESC key to exit the menu and return to the main display After exiting this menu the captured peak value will not be lost 4 5 TARE SCREENING Press the key to...

Page 8: ...e printing format to be taken from the printer is selected according to the product used These formats are separate for Dynamometer and Axle Scale WEIGHT REPORT WEIGHT 1 200 kg Date 23 03 2021 Time 08...

Page 9: ...value is selected as 0001 or 0002 or 0003 You can browse through the menus with the OK key 5 1 PARAMETER SETTINGS 5 1 1 Language Device language is changed 0003 With 0003 the crane hoist system equip...

Page 10: ...turned off with the power button 5 1 3 Match Equipment The equipment that will work with the hand terminal is selected 5 1 4 Stable Duration Indicates the time at which the weight weight data becomes...

Page 11: ...the screen It can be changed to kg t lb kN 5 1 8 Number of Transmitters The number of transmitters used is entered Maximum 16 transmitters are entered 5 1 9 Reset Percentage Indicates in which state...

Page 12: ...Channel assignment is made for the transmitter used in the load cell The transmitter to be assigned channels is kept open and the others are turned off 5 1 12 Number Setting Number assignment is made...

Page 13: ...5 1 13 Time Clock setting can be made with the up down right left buttons 5 1 14 Date Date setting can be made with the up down right left buttons...

Page 14: ...crane hoist system It can be selected from 0 to 5 If the hardware rope is desired to be changed the password 0003 is entered as below without the need to perform a recalibration process and the desire...

Page 15: ...0 000 000 5 2 4 LoadCell Capacity The maximum capacity value of LoadCell is entered Example 10000 kg 5 2 5 Calibration processes For load calibration or mV calibration the relevant transmitter is left...

Page 16: ...alibration a calibration load of at least 1 3 of the capacity is placed on the platform and the OK key is pressed In the menu displayed in load calibration the loaded internal count value is taken the...