background image

Battery and cap

SPECIFICATIONS

Model No.: 

KN 5025.

Square

 driver (inches): 

1/2” (12.7 mm).

Length: 

650 mm.

Max. operation ranger:

340 N-m / 250.7 ft-lg / 3009 in-lb / 3 469 kg-cm.

Accuracy

±2% - CW / ±3% - CCW.

Bright LED:

 

12 LED / 4 Reds + 8 Greens.

Operation mode: 

Peak hold / Track.

Unit selection: 

N-m, ft-lb, in-lb, kg-cm.

Head type: 

Lever Type Ratchet.

Gear teeth: 

36.

Button: 

4.

PC connectivity: 

No.

Battery: 

AA x 2.

Battery

 life (continuous operation) *2: 

110 hrs.

Battery

 life (standby) *2: 

1 year.

Operating temperature: 

-10º c ~ 60º c.

Storage temperature: 

-20º c ~ 70º c.

Humidity: 

Up to 90% noncondensing.

Drop

 test: 

1 m.

Vibration test *3: 

10 G.

Life time *4: 

10000 cycle.

Environmental test *5: 

Pass.

Electromagnetic compatibility test *6: 

Pass.

Note:

*1: The accuracy of the readout is guaranteed from

     20% to 100% of maximum range + /- 1

     increment. The torque accuracy is a typical

     value. Calibration point is at the middle line of

     black circle area on the rubber grip. For

     maintaining accuracy, calibrate the wrench at

     regular intervals (1 year recommended). And 

     the accuracy is based on the zero degree of

     offset from perpendicular drive.
*2: Use two AA batteries (Tested condition:

     Toshiba carbon-zinc R6UG battery).
*3: Horizontal and vertical test.

*4: One cycle means turning the torque wrench

     from 0 N-m to maximum range and back

     to 0 N-m.

*5: Environmental

 test:

     a. Dry 

heat

     b. Cold
     c. Damp heat
     d. Change of temperature

     e. Impact (shock)
     f.  Vibration

     g. Drop

*6: Electromagnetic compatibility test:
     a. Electrostatic 

discharge immunity (ESD)

     b. Radiation susceptibility
     c. Radiation emission

BEFORE USING THE WRENCH

BATTERY INSTALLATION
 •  Remove

 the battery cap.

 •  Insert two R6/AA batteries matching the -/+

    polarities of the battery to the battery

    compartment.

 •  Replace the battery cover and rotate it tightly

     according to the following figures.

 •  Press          to power on the digital torque wrench.

 •  Usually press         to reset the digital torque

     wrench before using it.

ATTENTION:

     If an external force is applied to the torque

     wrench during power-on/reset or wake up

     period, an initial torque offset will exist in the

     memory.

POWER ON AND RESETTING THE WRENCH

Summary of Contents for KN 5025

Page 1: ...KN 5025...

Page 2: ...ack mode selectable Buzzer and LED indicator for the pre settable target torque NAMES AND FUNCTIONS OF PARTS Engineering units N m ft lb in lb kg cm selectable Auto Sleep after about 5 minutes idle Re...

Page 3: ...brate the wrench at regular intervals 1 year recommended And the accuracy is based on the zero degree of offset from perpendicular drive 2 Use two AA batteries Tested condition Toshiba carbon zinc R6U...

Page 4: ...he wrench will display a battery symbol and then turn off Replace batteries SETUP STEP 1 UNIT SELECTION Pre setting unit N m Press Unit selection in lb Press Unit selection ft lb Press Unit selection...

Page 5: ...ED will illuminate 3 When the target torque has been reached the red LED will also illuminate Setting target torque Apply torque Current max value Peak hold Reached 90 of target torque START System in...

Page 6: ...s such as alcohol or paint thinner when cleaning the wrench 8 Keep this wrench away from magnets 9 Do not expose this wrench to dust or sand as this could cause serious damage 10 Do not apply excessiv...

Page 7: ...ES Y FUNCIONES DE LAS PIEZAS Alarma e indicador LED para la pre programaci n torque de objetivo Unidades de ingenier a N m ft lb in lb kg cm a seleccionar Auto suspensi n luego de 5 minutos sin uso Co...

Page 8: ...ra mantener la precisi n calibre la llave a intervalos regulares se recomienda una vez al a o Y la precisi n se basa en el grado cero de desbalance desde el accionador perpendicular 2 Use dos pilas AA...

Page 9: ...luego se apagar Reemplace las pilas CONFIGURACION PASO 1 SELECCI N DE UNIDAD Unidad Pre configurada N m Presionar Selecci n de unidad in lb Selecci n de unidad ft lb Selecci n de unidad kg cm Notas1y...

Page 10: ...e iluminar 3 Cuando se llega al objetivo de torque se iluminar el LED rojo tambi n Establecer el torque objetivo Aplicar torque Valor m x actual mantener m ximo Alcanz el 90 del objetivo del torque In...

Page 11: ...s org nicos como alcohol o disolvente al limpiar esta herramienta 8 Mantenga la llave alejada de magnetos 9 No la exponga a polvo o arena ya que esto podr a causar da os serios 10 No aplique fuerza ex...

Page 12: ...www knova com mx...

Reviews: