Start-up  

When CT901R is shipped from the factory, the display is off.  
CT901R is plugged into an electrical outlet, after which the display lights up. 
CT901R should be on at all times, so it should be mounted in a fixed electrical outlet. 
CT901R has a built-in battery backup. 
If the display shows "Clock not set", the clock should be set. See "S

etting the clock

" on page 4. 

 

General information about programming the CT901R 

Enter the Main Menu by holding down both arrow buttons for 3 seconds 

 

 
Then you can navigate up and down with the green arrow buttons. 

A menu line is selected with  

 

 
"

" shows the active row. 

"

" at the bottom of the screen indicates that you can scroll further down. 

"

" at the top of the screen indicates that you can scroll further up. 

"

" shows that the value can be changed with the arrow buttons. 

An entry is saved with 

 

You jump back to the previous menu with 

 

 
 
 

Setting the clock 

Enter the Main Menu by holding down both arrow buttons for 3 seconds. 

Navigate to the "Clock" menu and press  

 Then set the clock using the arrow buttons. 

 

 

 

 
 

 

The clock is not 

set 

 

 

System OK

 

or

 

11:08

 

6th March

 

 

 

System OK

 

˅

 

˄

 

3 sec.

 

   CT901 BED 

 Log file 

  Clock

 

  Light

 

  LS-901

 

 

Sender                     

 

Ent 

Ent 

Esc 

Ent 

   CT901 BED  
  Log file 

 Clock

 

  Light

 

  LS-901

 

 

Sender                   

 

Clock: 

 Hour 

:12 

  Minute  :45

 

  Day 

:ons

 

  Date 

:6

 

 

Month  :Mar               

Clock 

 Minute  :45

 

  Day 

:Wed

 

  Date 

:6

 

 

Month  :Mar 

 Year 

:2019             

Summary of Contents for CT901-BED

Page 1: ...OP Elektronik A S Fabriksvej 20 DK 7600 Struer knop knop dk knop dk 45 97840444 THIS MANUAL APPLIES TO THE SOFTWARE VERSION 3 X User manual for CT901 BED Contains CT901R TX901 D4106011A_8pin Relay cab...

Page 2: ...ck 4 Setting the light 5 Time management 6 Switching off the device 7 Log history 7 Programming encoding of bed guard 8 Co encoding of TX901 and CT901R 8 System test 9 Voltage drop of 230 Vac 9 Bad or...

Page 3: ...2 Place CT901R control unit in a wall socket so that it lights up 3 Connect the relay cable to the control unit and to the existing alarm system Points 4 to 8 are factory set if the units are purchase...

Page 4: ...and down with the green arrow buttons A menu line is selected with shows the active row at the bottom of the screen indicates that you can scroll further down at the top of the screen indicates that...

Page 5: ...ight slave LS901 If you wish to use the CT901R to light up an apartment e g when a patient gets up at night you can place up to 5 additional light slaves in different rooms all of which light up when...

Page 6: ...r can go to bed and rest in the middle of the day without the light and alarm being activated when the person gets up If time control is not activated the light is switched on and the alarm is activat...

Page 7: ...g It shows a list of the last 100 events with type time and date The last line shows Delete log select the line with and press to delete the log Types of activities S Bed guard alarm t Have been out o...

Page 8: ...an choose different settings Light move the green arrow downwards to No light and press Ent Then use the arrow buttons to change the value The No light light never comes on Light time means that the l...

Page 9: ...multiple error messages scroll with the up down arrow The system tests the following elements Voltage drop of 230 Vac Bad or no battery in CT901R and encoded LS901 units Bad battery in encoded Transmi...

Page 10: ...rce LED adjustable from 0 100 Approx 100 lumen max Lightslaves Connection of 5 additional LS901 light slaves wirelessly Sender Encoding of 1st transmitter in Knop s 900 901 series Log history Saves th...

Reviews: