Knoll Tone Electric Assembly Instructions Manual Download Page 7

7

 

07.17

 

ASSEMBLY

 

INSTRUCTIONS

 

 

(Fig. 11)     Electrical 3

Column 120

 

Warning

 

lea

fl

et

 

and

 

user

 

manual

 

should

 

be

 

le

 

on

 

the

 

table

 

a er

 

completed

 

installa on.

 

Warning

 

Lea

fl

et

 

Tone

 

Electric

 

User

 

Manual

 

Tone

 

Electric

  

KR68002414

 

/

 

KR68003122

 

KR68002583

 

/

 

KR68002489

 

Cable

 

LinBus

 

iDrive

 

800

 

/

 

1200

 

/

 

1600

 

/

 

2000

 

KR3ae4025

 

ASM

 

Light

 

Handset

 

w

 

Screws

 

KR68003761

 

Power

 

Supply

 

D04

 

35V/2,12A

 

AC

 

input

 

100

240V,

 

50

60Hz

 

KR68002262

 

Cable

 

USA

 

2

pol

 

IEC

 

C7

 

DIN

 

57625

 

 

 

KR79100380

 

P

clips

 

must

 

be

 

installed

 

to

 

secure

 

any

  

cables

 

hanging

 

down

 

more

 

than

 

1.5

 

inches

 

from

 

the

 

bo om

 

of

 

the

 

work

 

surface

 

Summary of Contents for Tone Electric

Page 1: ...s may differ in appearance and func onality but the assembly principle is the same Tone Electric and Extended Electric Complete product without work surface Complete product with work surface 120 90 90 120 Housing Sidebar Crossbar Column Foot Cau on No impact drivers or other high torque equipment are to be used ...

Page 2: ...2 stage columns In Foot OnC for 3 stage columns In Foot OffC for 3 stage columns Do not use the two middle holes of the crossbars Adjustable crossbar Fixed crossbar KR68003496 Screw Socket Round UNC 5 16 18x5 8 Zn Maximum Torque from 3 to 5 lbf KR68003490 Screw Socket CSK UNC 5 16 18x1 Zn Loosen Screws to adjust crossbar length ...

Page 3: ...R3ae4014R Right Symmetric Sidebar for T leg Part number KR3ae4015 KR68003468 Bumper 1 2 x1 2 x1 4 Transparent KR68003467 Bumper Ø1 2 x1 8 Transparent Place thin bumpers on tube next to Screw hole and next to tube edge Place thick bumpers on C channel next to Screw hole KR79100036 Screw Philips Undercut Flat Head 1 4 20x5 8 Zn ...

Page 4: ...rs for 3 column 90 table 3 regular fixed crossbars 1 regular fixed crossbar 6 shorter than the other three crossbars 1 addi onal assembly kit KR68003491 Screw Socket CSK UNC 5 16 18x1 1 2 Zn Alterna ve foot Special telescopic crossbar Regular fixed crossbar Regular fixed crossbar Regular fixed crossbar 6 shorter than the other three crossbars Alterna ve foot KR68003491 Screw Socket CSK UNC 5 16 18...

Page 5: ...stable crossbars 2 Brackets KR3AE4121 Bracket Outer KR3AE4120 Bracket Inner Fixed crossbars for 3 column 120 table 4 regular fixed crossbars 2 Brackets KR3AE4121 Bracket 120 Outer KR3AE4120 Bracket 120 Inner KR68005205 Hex Nut UNC 5 16 18 Zn KR68003490 Screw Socket CSK UNC 5 16 18x1 Zn KR68003490 Screw Socket CSK UNC 5 16 18x1 Zn KR68005205 Hex Nut UNC 5 16 18 Zn ...

Page 6: ...z KR68002414 KR68003122 KR68002583 KR68002489 Cable LinBus iDrive 800 1200 1600 2000 KR3ae4025 ASM Light Handset w Screws KR68002414 KR68003122 KR68002583 KR68002489 Cable LinBus iDrive 800 1200 1600 2000 KR3ae4025 ASM Light Handset w Screws KR68003761 Power Supply D04 35V 2 12A AC input 100 240V 50 60Hz KR68002262 Cable USA 2 pol IEC C7 DIN 57625 KR79100378 KR79100379 P clips must be installed to...

Page 7: ...ser Manual Tone Electric KR68002414 KR68003122 KR68002583 KR68002489 Cable LinBus iDrive 800 1200 1600 2000 KR3ae4025 ASM Light Handset w Screws KR68003761 Power Supply D04 35V 2 12A AC input 100 240V 50 60Hz KR68002262 Cable USA 2 pol IEC C7 DIN 57625 KR79100380 P clips must be installed to secure any cables hanging down more than 1 5 inches from the bo om of the work surface ...

Page 8: ...ot use thick bumpers on fixed width crossbars The thin bumpers are placed on fixed width crossbars and should be spaced evenly between the sidebars in order to prevent the work surface from bowing The work surface will rest upon the bumpers on the crossbars and directly upon the sidebars without bumpers WORK SURFACE Two sizes of wood screws for the work surface are included in the assembly kit KR6...

Page 9: ...s that a ach to the middle column The assembly procedure is the same as for a 2 column table The 120 brackets are a ached with bolts and nuts Fig 9 11 ELECTRONICS The handset is mounted at the front edge of the work surface screwed to the underside with screws supplied with the unit Connect cables and power supply according to fig 9 11 ...

Page 10: ...eriod of 1 minute and then has come to a halt Wait 9 minutes to let the table cool down and try again If it s ll does not work a er 5 min Try disconnec ng power for about 20 s and reconnect If there is s ll no func on Replace handset and check all connected cables If there is s ll no func on Replace column 2 Table running slow 2 1 Slow speed both up and down If possible measure power consump on on...

Page 11: ... not moving in sync 5 1 Only one motor moving Disconnect from power then reconnect all cables 5 2 One motor running uncontrolled and other motor just running 2 inches up or down Replace the column 5 3 Table moving up and down normally but table top not parallel to floor Ini ate a new homing cycle by holding the up and down bu ons pressed at the same me for 8 seconds Drive the table all the way dow...

Page 12: ...nd black and white text minor changes PERLOH Rev F 2015 03 03 Fig 3 79100036 was 68003465 JONLAR Rev G 2016 04 26 Wood screws Fig 4 changed LINPHA Revised wood screws in Fig 4 Page 8 Revised screw types in Fig 5 6 7 8 Reworded bumper instruc ons in Fig 4 Page 8 New bracket outer inner on Pages 1 5 7 Added P Clips in Fig 9 10 11 on pages 6 7 Added warnings on page 10 Updated handset drawings on Pag...

Reviews: