background image

 

 

 

Keypad Connection 

The GSZ67 outputs can be controlled by the MR164 keypad and/or an external 
controller or computer (using the RS232 port), so keypads may not be needed. 

 
More than one or two keypads can be used in a zone and nine (9) is the 
maximum number of MR164 keypads per GSZ67 allowed.  
 
 

Note: MR164 keypads are not designed for outdoor use, high humidity, 
high temperatures or any extremes.  

 
 
The MR164 contains an almost all brand infrared repeater and most functions can be 
controlled by the Knoll RB12 remote control. RB12 commands can easily be stored in 
a learning remote.  
 
The MR164 is connected to the GSZ67 with CAT5 or CATe wire. Each keypad can 
have a home run or be daisy chained on one wire. 

If you daisy chain one zone 

and another zone on one wire you may lose some infrared functionality.

 

Each room or zone has a unique IR pass-thru port as indicated on the rear of the 
GSZ67. In addition there is an all room IR pass-thru port. If you combine two or 
more rooms or zones on 1 CAT5 wire the ability to individually split infrared signals 
will be lost. Each keypad has two RJ45 connectors that are both inputs and outputs 
for daisy chaining keypads together. Five of the eight CAT5 wire conductors are 
used.  
 
 

 

 

Note: It is very important to use a top quality  
RJ45 8/8 crimper tool. We strongly suggest  
using a cat 5 / RJ45 electronic tester to verify  
the wire conductors.

  

 

We recommend the T568A wiring method, which is shown below.  

The functions of each wire connection are also shown. 

 

                                                             future use brown 

                                                 future use  white/brown 
  

 

 

                    Infrared orange 

               ground white/blue 

           +12 vdc blue 

                                   future use white/orange 

                                                                      SDA green 

                  SCL  white/green

 

 

 
 
 

 
 

 

Summary of Contents for GSZ67

Page 1: ...GSZ67 12 Channel Eco System Controller Amplifier Installation Instructions v1 3...

Page 2: ...storms or when unused for long periods of time 14 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or p...

Page 3: ...between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician fo...

Page 4: ...pment The GSZ67 is normally controlled by MR164 LCD keypads with or without Knoll remote controls or RS232 commands from whole house controllers The paging override is normally used for whole house an...

Page 5: ...amaged during shipping please contact your dealer or Knoll immediately and request the name of the carrier so a written claim can be made The right to a claim against a public carrier can be forfeited...

Page 6: ...and degradation in performance To connect the amplifiers to your speakers a removable plug with screws is provided for each stereo channel output Strip approximately 1 4 inch of insulation from the en...

Page 7: ...by request all enclosed in parentheses The request can be in some cases a read request followed by a or a write request followed by 0 3 ASCII digits A read command will return the current setting and...

Page 8: ...y Unmute num n 1 6 write only Mute All amu none write only Unmute All aum none write only Vol nvl Or n 1 6 read or write note 1 0 80 Vol All avl 0 80 write only Input Select nsl n 1 6 write only 1 7 I...

Page 9: ...sy chain one zone and another zone on one wire you may lose some infrared functionality Each room or zone has a unique IR pass thru port as indicated on the rear of the GSZ67 In addition there is an a...

Page 10: ...5mm mono jack DATA IN and DATA OUT connections On the rear of the GSZ67 amplifier there are two 3 5mm stereo jacks labeled DATA IN and DATA OUT These ports connect two or more GSZ67 s together so the...

Page 11: ...powered up it is time to let the amplifier and keypads know which rooms are which Go to the first keypad connected to room 1 Keypad is connected to KEY1 and speakers are connected to SPEAKERS 1 The k...

Page 12: ...o enter the installer menu from System Off press the keypad MUTE button for about 1 second then immediately press the INPUT for about 5 seconds Release the INPUT button as soon as the LCD displays Sou...

Page 13: ...easy nighttime operation To adjust the backlighting make sure the power for the keypad is on and the MR164 is off not playing any sources The LCD display then displays System Off Without pressing any...

Page 14: ...us for assistance Problem Solutions Amplifier won t turn on Master power switch turned off No power light LED Turn on Master Power Switch Amplifier turns on but no audio Input plugs not connected to...

Page 15: ...ND EXCLUSION Knoll shall have no further obligation under the foregoing limited warranty if the Product has been damaged due to abuse misuse neglect accident unusual physical or electrical stress unau...

Page 16: ...urce 1______________________ Source 2_____________________ _ Source 3______________________ Source 4_____________________ _ Source 5______________________ Source 6_____________________ _ Source 7_____...

Reviews: