background image

2

These instructions should be read carefully and retained after installation by the end user for future 
reference and maintenance.
These instructions should be used to aid installation of the following products:
WALL1L, WALL2L, WALL3L, WALL1LC, WALL2LC, WALL3LC

GENERAL INSTRUCTIONS

SAFETY

GENERAL SPECIFICATIONS

•  Installation of this luminaire should only be carried out by a qualified electrician or competent 

person to the latest Building and current IEE Wiring Regulations (BS7671)

• Please isolate mains prior to installation/maintenance
•  Check the total load on the circuit (including when this luminaire is fitted) does not exceed the 

rating of the circuit cable, fuse or circuit breaker

•  Please note the IP (Ingress of Protection) rating of this luminaire when deciding the location for 

installation

• This product is class I and requires an earth 
• This product series is IP65 rated

•  Provide power to the required point of installation. Suitable IP rated junctions boxes should be used 

where required

• Using a 7mm spanner, remove the two nuts securing the baseplate of the luminaire (see Fig 1)

•  Using the baseplate as a template, mark the location of the fixing holes and drill the holes ensuring 

not to infringe with any joists, gas or water pipes or electrical cables

•  Feed the mains cable through the rubber grommet to retain IP rating, and secure baseplate to the 

desired surface

• Ensuring correct polarity is observed, carefully wire as shown in Fig 2

Remove nuts

Fig 1

(WALL2L shown)

WALL L AND WALL LC INSTRUCTIONS_WEB.indd   2

25/01/2017   13:15