INSTALLATION & MAINTENANCE MANUAL 

These instructions should be read carefully and retained after installation by the end user for future reference 

and maintenance. 

These instructions should be used to aid installation of the following products:  

LEDM07B / LEDM07W

 

SAFETY 

 

This product must be installed in accordance with the latest edition of the IEE Wiring Regulations 

(BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician 

 

Please isolate mains prior to installation or maintenance 

 

Check the total load on the circuit (including when this product

 

is fitted) does not exceed the rating of 

the circuit cable, fuse, or circuit breaker 

 

Please note the IP (Ingress Protection) rating of this product when deciding the location for installation 

 

This product is safe for use as a drive-over fitting

 

(800kg @ 5mph) 

 

This product is Class I and must be earthed 

 

This product is IP65 rated 

INSTALLATION 

Note - If this product is being used in conjunction with an external PIR or sensor, please confirm with the 

manufacturer of the sensors that they are compatible with LED luminaires. 

 

Provide power to the required point of installation (refer to BS7671 for correct cabling methods). 

Suitable IP rated junction boxes should be used where required 

 

The power source connections should be local and accessible via a suitable IP rated enclosure 

 

Cut a suitable hole in the mounting surface as per the cut-out details (see Fig.1) ensuring not to 

infringe with any joists, gas/water pipes or electrical cables  

 

 

Cut-out with sleeve 

Cut-out without sleeve 

60mm 

50mm 

Fig. 1 

 

We recommend not installing in areas where there is a high risk of flooding or areas where water may 

sit on top of the fitting (see Fig. 2) 

 

Ensure a minimum of 300mm of drainage is put below the luminaire (see Fig. 2) 

Cut-out with sleeve

Cut-out without sleeve

60mm

50mm

Fig. 1

• We recommend not installing in areas where there is a high risk of flooding or areas where water may sit on 

top of the fitting (see Fig. 2)

• Ensure a minimum of 300mm of drainage is put below the luminaire (see Fig. 2)

 

 

Fig. 2 

 

There must be enough cable below the luminaire to carry out maintenance work (see Fig. 3) 

 

 

Fig. 3 

 

Connect the luminaire to the mains supply ensuring the correct polarity is observed L - Live (brown), E 

- Earth (green/yellow), N - Neutral (blue). 

 

 

Switch on and check for correct operation 

WARNING 

This product must be disconnected from the circuit if subjected to any high voltage or insulation resistance 

testing. Irreparable damage will occur to the lamp if this instruction is not followed. 

Care should be taken when installing into high ‘clay’ content soils which naturally retain water and have poor 

drainage. We recommend IP67 or IP68 products to be installed where these environmental conditions occur as 

IP65 luminaires will likely be compromised. 

This product is not suitable for installation in or near a coastal or marine environment. 

GENERAL 

The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole 

luminaire should be replaced.  

Clean the external surfaces with a damp cloth using a mild solution of detergent and warm water only, do not 

use aggressive cleaning products or solvents which may damage the product.   

Do not use any source of high-pressure washers to maintain or clean this luminaire. 

• There must be enough cable below the luminaire to carry out maintenance work (see Fig. 3)