0901225 Rev: X6 (draft 10/09/20)
Page 7 of 12
PRE
-
RELEASE COPY
--
NOT FOR DISTRIBUTION
MAINTENANCE
•
Periodically check the electric pump for leaks or evidence of wear/breakdown.
•
Periodically check the hose connections to main unit and to nozzle to assure they are tight.
•
Clean and/or replace air filter on air compressor annually.
•
Check filter strainer inside tank and clean off any debris as needed.
AFTER
-
USE
(1)
[Fig. J] Empty tank by opening the drain valve at rear
of unit to allow contents to exit tank into an
appropriate drain.
(2)
Rinse the tank with fresh water thoroughly while drain
valve remains open.
(3)
[Fig. J] Close drain valve and add enough water to fill
approximately 1 inch within the tank.
(4)
Plug electrical cord into a nearby outlet. Turn main
power on. Point gun nozzle into the open tank and
press and hold the Prime button as a stream of water
will flow through nozzle and into tank flushing any
contents from the internal components and lines
leading to nozzle gun. Repeat step 1 to empty tank.
(5)
[Fig. K] Wrap the power cord around the holder on the
back of the cart for transporting to a different location.
CAUTION: Do not move the cart by pulling on the
sprayer hose or the power cord. Do not lift the unit or
pull it up a staircase by the handle.
(6)
[Fig. L] Hang the sprayer on the hook provided on the
handle.
Figure
J
Figure
K
Figure