SAFETY PRECAUTIONS
Read and understand the MSDS sheets for the cleaning chemicals that will be used — consult your chemical
supplier if you have any questions.
Always wear safety goggles and protective gloves while operating the foam unit.
Avoid contact of cleaning agents with skin and eyes. If contact occurs, rinse affected area with water for 15
minutes, and seek medical attention, if needed.
Drain fluid contents of unit and flush out tank if using different types of chemicals from operation to operation.
Never point the Discharge Foam Wand at anyone.
Be sure to flush unit with fresh water when switching from alkaline to acid, or acid to alkaline product.
Never leave unit unattended while discharge hose is under pressure.
Never foam directly into an uncovered electrical outlet or electrical panel.
Stand far enough away from surface being foamed to prevent foam from splashing on you.
AFTER-USE
(1) Fill the tank with fresh water and rinse thoroughly. With discharge valve ―open‖, allow pump to run until all
chemical has been pumped through discharge hose, and air has been purged.
(2) Close the Air Inlet Valve and relieve all remaining pressure on the unit by opening the valve on the discharge
hose and leave in the ―open‖ position.
(3) Open the drain plug on the bottom of the tank to remove any remaining liquid from the tank. The drain plug is 1‖
NPT with a 1.375‖ hex head.
MAINTENANCE
Periodically check the air pump for leaks or evidence of wear/breakdown.
Periodically replace filter media in filter/dryer.
Periodically check the pickup tube for blockage, and flush to clean.